  • Code: 998
  • Description: Application start error
    No applications start within 60 seconds after the power is turned on.
  • Causes: • Loose connection of RAM-DIMM, ROM-DIMM • Defective controller • Software problem
  • Remedy: 1. Check the setting of SP5-875-001. If the setting is set to "1 (OFF)", change it to "0 (ON)". 2. Check if the RAM-DIMM and ROM-DIMM are correctly connected. 3. Reinstall the controller system firmware. 4. Replace the controller board.