Catalog
Sign In
Contacts
Forum
Eng
Ricoh D045 MPC1800 PG-C2
Error Codes List page 1
Error Code:
All codes
101-001
101-002
120
121
141
142
144-001
144-002
144-003
144-004
161-001
161-002
165
200
202
210
211
503
504
506
520
570
571
572
573
610
620
630
632
633
634
635
636
650
651
669
670
672
685
686
687
818
819
820
821
822
823
824
826
827
828
829
838
851
853
854
855
856
857
860
861
863
864
865
866
867
868
870
872
873
874
875
876
877
880
900
920
921
925
990
991
992
997
998
page
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Code: 101-001
Description: Exposure lamp error Shading at AGC The shading data peak does not reach the specified threshold (64/255 degit) when the machine executes the shading at initialization.
Causes: • Defective exposure lamp • Defective lamp stabilizer • Defective exposure lamp harness
Remedy: 1. Replace the exposure lamp. 2. Replace the lamp stabilizer. 3. Replace the exposure lamp harness.
Code: 101-002
Description: Exposure lamp error Shading at scanning The shading data peak does not reach the specified threshold (64/255 degit) when the machine executes the shading at scanning.
Causes: • Defective exposure lamp • Defective lamp stabilizer • Defective exposure lamp harness
Remedy: 1. Replace the exposure lamp. 2. Replace the lamp stabilizer. 3. Replace the exposure lamp harness.
Code: 120
Description: Scanner home position error 1 The scanner home position sensor does not detect the “OFF” condition during operation.
Causes: • Defective scanner motor drive board • Defective scanner motor • Defective home position sensor • Defective harness
Remedy: 1. Replace the scanner motor drive board. 2. Replace the scanner motor. 3. Replace the scanner HP sensor. 4. Replace the harness.
Code: 121
Description: Scanner home position error 2 The scanner home position sensor does not detect the “ON” condition during operation
Causes: • Defective scanner motor drive board • Defective scanner motor • Defective home position sensor • Defective harness
Remedy: 1. Replace the scanner motor drive board. 2. Replace the scanner motor. 3. Replace the scanner HP sensor. 4. Replace the harness.
Code: 141
Description: Black level detection error The black level cannot be adjusted within the target value during the zero clamp after the AGC.
Causes: • Defective SBU • Defective harness
Remedy: 1. Replace the harness. 2. Replace the SBU. 3. Replace the BICU.
Code: 142
Description: White level detection error The white level cannot be adjusted within the target value during the zero clamp after the AGC.
Causes: • Defective SBU • Defective harness
Remedy: 1. Replace the exposure lamp. 2. Replace the lamp stabilizer. 3. Replace the harness. 4. Replace the SBU.. 5. Replace the BICU