- Code: 827
- Description: Self-diagnostic Error: RAM
The resident RAM returned a verify error during the self-diagnostic test.
- Causes: Download controller firmware again
- Code: 828
- Description: Self-diagnostic Error: ROM
The resident read-only memory returned an error during the self-diagnostic test.
- Causes: • Controller board defective • Download controller firmware again
- Code: 829
- Description: Self-diagnostic Error: Optional RAM
The optional RAM returned an error during the self-diagnostic test.
- Causes: • Replace the optional memory board • Controller board defective
- Code: 835
- Description: Self-Diagnostic Error: Parallel Interface
Loopback test error.
- Causes: • Loopback connector not detected • IEEE1284 connector defective • Controller board defective
- Code: 836
- Description: Self-diagnostic Error: Resident Font ROM
The resident font ROM returned an error during the self-diagnostic test.
- Causes: Replace the controller board
- Code: 837
- Description: Self-diagnostic Error: Optional Font ROM
The optional font ROM returned an error during the self-diagnostic test.
- Causes: Replace the controller board