  • Code: SC901
  • Description: Bk-total counter not off - Definition - [B] The Bk-total counter does not turn off.
  • Causes: • Bk-total counter defective
  • Code: SC902
  • Description: FC-total counter does not turn on - Definition - [B] The FC-total counter does not turn on or off.
  • Causes: • FC-total counter defective
  • Code: SC903
  • Description: FC-total counter does not turn off - Definition - [B] The FC-total counter does not turn on or off.
  • Causes: • FC-total counter defective
  • Code: SC910 ... SC917
  • Description: SC910: ACC Calculation Error (Letter Mode: Bk) SC911: ACC Calculation Error (Letter Mode: C) SC912: ACC Calculation Error (Letter Mode: M) SC913: ACC Calculation Error (Letter Mode: Y) SC914: ACC Calculation Error (Photo Mode: Bk) SC915: ACC Calculation Error (Photo Mode: C) SC916: ACC Calculation Error (Photo Mode: M) SC917: ACC Calculation Error (Photo Mode: Y) - Definition - [D] Even if the test pattern has been scanned in, the CPU on the IPU could not find the appropriate adjustment table to approximate the actual curve to the target gamma curve.
  • Causes: • IPU defective
  • Code: SC920
  • Description: ACC not performed (internal error) - Definition - [D] Under any of the following conditions, the ACC will not performed. 1) Process Control self-check error, ID sensor error, Drum potential sensor error, Potential control error. 2) When an SC occurs while the ACC test pattern is printed. 3) When the TD sensor output (Vt) value becomes lower than 2.5 ± 1.0 V.
  • Causes: • The actual printer gamma curve changed over a big range (caused by process control self-check). • Main Control Board defective