Catalog
-
Sign In
-
Contacts
-
Forum
-
Eng
OKI ES1220n
Error Codes List page 7
|
|
- Code: 220
- Display: Service call 220:Error
- Description: False setting of a record medium detected by a print statistics.
- Causes: Take off the HDD or replaced?
- Remedy: Reset original HDD.
- Code: 901, 902
- Display: Power off/on 901:Error 902:Error
- Description: Short or open in belt thermistor detected.
- Causes: Is belt thermistor cable setting proper? Does error reoccur?
- Remedy: Connect cable set properly again. Turn power ON again. Replace belt thermistor.
- Code: 903, 904
- Display: Power off/on 903:Error 904:Error
- Description: Abnormal temperature detected by belt thermistor (high-temp or low temp.)
- Causes: Is belt thermistor cable setting proper? Does error reoccur?
- Remedy: Connect cable set properly again. Turn power ON again. Replace belt thermistor and leave aside for 30 min. Then turn power ON again.
- Code: F0C, F0D, FFE, FFF
- Display: Power off/on 203:Error 204:Error 207:Error 208:Error 210:Error ~ 214:Error F0C:Error F0D:Error FFE:Error FFF:Error
- Description: An error was detected of the CU program. (203~214 is not occure in usual operating.)
- Causes: Reinstall the CU board. Is the error message displayed again?
- Remedy: After turn power OFF, check connections between CU board and PU board. Then turn power ON again.