Catalog
-
Sign In
-
Contacts
-
Forum
-
Eng
OKI C5400n
Error Codes List page 11
|
|
- Code: 908
- Display: Service call 908:Error
- Description: A low temperature error (below [environmental temperature minus 10]°C) of frame thermistor detected.
- Causes: Does error reoccur?
- Remedy: Turn power ON again. Replace the fuser unit.
- Code: F0C, F0D, FFE, FFF
- Display: Power off/on 203:Error 204:Error 207:Error 208:Error 210:Error ~ 214:Error F0C:Error F0D:Error(C5400 only) FFE:Error(C5400 only) FFF:Error
- Description: An error was detected of the CU program. (203~214 is not occure in usual operating.)
- Causes: Reinstall the CU board. Is the error message displayed again?
- Remedy: After turn power OFF, check connections between CU board and PU board. Then turn power ON again.