PrintCopy.info service

OKI C3530 MFP

Error Codes List page 7

  • Code: 230
  • Display: Service call 230: Error
  • Description: RFID Reader not Installed
  • Remedy: RFID Reader Device error. Does the error recur?
    Check the connenction of the LUM board (RFIS reader/writer board). Replace the LUM board (RFID reader/writer board). Replace the M32 board.
  • Code: 231
  • Display: Service call 231: Error
  • Description: RFID Reader I/F Error
    An interface error was detected with the RFID reader device.
    01: communication error between the RFID reader and the engine PCB.
    02:the transcever circuit error of the RFID reader.
    03:communication error between the RFID reader and the toner cartridge.
    04:the toner cartridge detection error (more than 4).
  • Remedy: 01: Same as Error 230. 02: Replace the LUM board (RFID reader/writer board). 03: Check the connection of the antenna cable. 04: Check if the number of toner cartridge is correct.
  • Code: 240
  • Display: Service call 240: Error
  • Description: Engine Program. Memory Error
    240: Flash Memory Hardware Error
  • Remedy: If the error occurs again after returning on the power supply, replace the board of the unit.
  • Code: 905, 906
  • Display: Service call 905: Error 906: Error
  • Description: Short circuit error of the Frame thermistor (thermistor defect) is detected
  • Remedy: Does the error recur? Yes Check the cable connection between the ZAK board and M32 board and turn on the power again. Replace the fuser unit. Replace the M32 board.
  • Code: 907
  • Display: Service call 907: Error
  • Description: High temperature error of the frame thermistor (over 150)is detected
  • Remedy: Does the error recur? Yes Check the cable connection between the ZAK board and M32 board and turn on the power again.Replace the fuser unit. Replace the M32 board.
  • Code: 908
  • Display: Service call 908: Error
  • Description: Low temperature error of the Frame thermistor (lower than [environment temperature -10]) is detected
  • Remedy: Does the error recur? Yes Check the cable connection between the ZAK board and M32 board and turn on the power again. Replace the fuser unit. Replace the M32 board.
Error Code