  • Code: 104
  • Description: Engine EEPROM setting check was OK when power ON. Then detect read/ write error.
  • Remedy: Power Off/On. Replace the PU/ CU board
  • Code: 106
  • Description: Abnormal engine control logic.
  • Remedy: Power Off/On. Replace the PU/ CU board.
  • Code: 112
  • Description: Detected illegal 2nd Tray.
  • Remedy: Is a 2nd Tray provided for this model installed? No Install a correct 2nd Tray.
  • Code: 113
  • Description: Detected illegal 3rd Tray.
  • Remedy: Is a 3rd Tray provided for this model installed? No Install a correct 3rd Tray.
  • Code: 114
  • Description: Detected illegal 4th Tray.
  • Remedy: Is a 4th Tray provided for this model installed? No Install a correct 4th Tray.
  • Code: 121
  • Description: High-voltage power supply I/F error.
  • Remedy: Is cable between PU board and high-voltage power unit connected properly? Is there no improperly connections? No Yes No Connect properly. Check improper connections for high-voltage. Replace the higevoltage power supply.