Description: The operational life of Pump has almost expired.
Remedy: Check the condition of Pump. Replace Pump as necessary. Clear the counter after replacing it.
Code: n14
Display: Life Times [CR Motor]
Description: The operational life of CR motor has almost expired.
Remedy: Check the condition of CR motor. Replace CR motor as necessary. Clear the counter after replacing it.
Code: n15
Display: Life Times [PF Motor]
Description: The operational life of PF motor has almost expired.
Remedy: Check the condition of PF motor. Replace PF motor as necessary. Clear the counter after replacing it.
Code: n16
Display: Media cut error
Description: Even though cutting operation is performed, media is not cut off.
Remedy: 1. Does media dust accumulate in cutter groove? Remove accumulated media dust along groove. 2. Is cutter cap securely installed? Reinstall cutter cap securely. 3. Check cutter sliding up/down operation. 4. When setting cutter, lower cutter with finger and check that cutter rises to upper end only by spring force. • When it does not rise: Refer to action in check item No. 4. • When it rises: Refer to action in check item No. 5. 5. When setting cutter after removing cutter spring, does cutter lower to lower end by its own weight? • When it lowers: Cutter spring may be defective. Replace cutter spring referring to exploded views. • When it does not lower: Cutter may be defective. Replace cutter. 6. Check if solenoid goes up/down from "Life: Cutter" of self-diagnosis function. a) Goes up/down: Check the position where cutter goes down to cutter groove. b) Does not go up/down: • OK: Cutter has reached the end of life or be damaged. Replace cutter with new one. • NG: Adjust cutter holder position. Connector may be poorly connected. Check the connection of following connectors. 7. CR_FFC may be broken, solenoid may be defective, or each board may be defective. a) Replace CR_FFC with new one. If solenoid goes up/down, replace CR_FFC. b) Replace solenoid with new one. (Check by connecting connectors directly) If solenoid goes up/down, replace solenoid. c) Replace CR board. After replacement, adjust sensor reflection amount from "Sen: Edge AD" of "Test: Sensor" of self-diagnosis function. d) Replace MAIN board . Before replacing MAIN board, back up parameters and recover to new MAIN board . Then start operation check.