PrintCopy.info service

Mutoh ValueJet 1618

Error Codes List page 3

  • Code: E016-12
  • Display: E 016 error Overflow [12]
  • Description: Arithmetic overflow exception error: Overflow occurs
  • Remedy: 1. Check AC power supply and printer peripherals. 2. Check whether the same error occurs by turning ON/OFF the machine power several times. Make sure to perform this check repeatedly even if no problems seem to be present. (Make the same condition as user's.) 3. Check the serial number of the printer. 4. MAIN board assembly may be defective. Replace MAIN board assembly.
  • Code: E016-13
  • Display: E 016 error Trap [13]
  • Description: Trap exception error: Trap occurs
  • Remedy: 1. Check AC power supply and printer peripherals. 2. Check whether the same error occurs by turning ON/OFF the machine power several times. Make sure to perform this check repeatedly even if no problems seem to be present. (Make the same condition as user's.) 3. Check the serial number of the printer. 4. MAIN board assembly may be defective. Replace MAIN board assembly.
  • Code: E016-15
  • Display: E 016 error Floating [15]
  • Description: Floating point exception error: Abnormal condition in floating point process
  • Remedy: 1. Check AC power supply and printer peripherals. 2. Check whether the same error occurs by turning ON/OFF the machine power several times. Make sure to perform this check repeatedly even if no problems seem to be present. (Make the same condition as user's.) 3. Check the serial number of the printer. 4. MAIN board assembly may be defective. Replace MAIN board assembly.
  • Code: E016-32
  • Display: E 016 error WatchDog [32]
  • Description: Watchdog time-out exception error: Time-out in watchdog
  • Remedy: 1. Check AC power supply and printer peripherals. 2. Check whether the same error occurs by turning ON/OFF the machine power several times. Make sure to perform this check repeatedly even if no problems seem to be present. (Make the same condition as user's.) 3. Check the serial number of the printer. 4. MAIN board assembly may be defective. Replace MAIN board assembly.
  • Code: E016-33
  • Display: E 016 error Abort Err [33]
  • Description: Abort error: Process aborted
  • Remedy: 1. Check AC power supply and printer peripherals. 2. Check whether the same error occurs by turning ON/OFF the machine power several times. Make sure to perform this check repeatedly even if no problems seem to be present. (Make the same condition as user's.) 3. Check the serial number of the printer. 4. MAIN board assembly may be defective. Replace MAIN board assembly.
  • Code: E065
  • Display: E 065 error PF motor
  • Description: Abnormal condition in PF motor (X-axis) during printer operation. Displayed if the difference between motor command value and feedback from encoder is large.
  • Remedy: 1. Check error history from "Test 7: Record" of selfdiagnosis function. 2. Set the number of endurance running cycles to 50 or more from "Life 2: PF Motor" of selfdiagnosis function, and check if "PF motor error" occurs. Check the connection of the following MAIN board assembly connectors: • PF motor relay assembly connector: J20 • PF encoder assembly connector: J12 3. Check "Encoder: PF" from "Check 2: Test" - "Test 5: Encoder" of selfdiagnosis function. If NG, check the connection of MAIN board assembly connector: J12. 4. Is the area around PF encoder contaminated? Clean the area around PF encoder. If PF encoder is damaged, replace it. 5. Check if Main Power Board properly supplies DC24V. If the power board assembly is damaged, replace it. 6. PF motor assembly may be defective. Replace PF motor. 7. MAIN board assembly may be defective. Replace MAIN board assembly.
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us