Description: Abnormal condition in media feed amount (Xaxis) during plotter operation. Displayed if there is no feedback from encoder.
Remedy: 1. Check error history from "Test: Elec." of self-diagnosis function. 2. Set the number of endurance running cycles to 50 or more from "Life: PF motor" of selfdiagnosis function, and check if "X motor error" occurs. 3. Check "Encoder: PF" from "Test: Encoder" of selfdiagnosis function. 4. Check if Main Power Board normally supplies DC24V. 5. PF motor assembly may be defective. 6. Main board assembly may be defective. - Check connection of following main board assembly connectors. • PF motor cable assembly connector: J107 • PF_ENC assembly connector: J129 • If NG, check connection of main board assembly connector: J129. • Replace PF motor assembly. • Replace main board assembly.
Code: E068
Display: E068 error Y encoder
Description: Abnormal condition in head travel distance (Yaxis) during plotter operation. Displayed if there is no feedback from encoder.
Remedy: 1. Check error history from "Test: Elec." of self-diagnosis function. 2. Move carriage in both directions while the plotter is turned off, and check if there is any position where carriage does not move smoothly. 3. Set the number of endurance running cycles to 50 or more from "Life: CR motor" of selfdiagnosis function, and check if "Y motor error" occurs. - • Clean and lubricate CR rail roller guide. • Check connection of following connectors. Main board: • CR motor assembly connector: J106 • CR cable connector: J110 - J114 CR board: • CR cable connector: J201 - J205 • TF_ENC assembly connector: J210 4. Check if T fence is contaminated or worn out. • If grease or dust collect: Wipe fence with a dry cloth. • If ink deposit presents: Wipe it off with cloth dampened with neutral detergent. • If contamination or deposit is too heavy: Replace T fence. 5. Check "Y Encoder" from "Test: Encoder" of selfdiagnosis function. a) If NG: Check following cable connection. • CR board assembly connector J210 b) Replace following parts. • T fence • CR motor assembly • CR board assembly • CR cable • Replace main board assembly. 6. Main board assembly may be damaged.
Code: E069
Display: E069 error X time-out
Description: Time-out condition in media feed amount (Xaxis) during plotter operation. Displayed if pressure roller does not reach the defined position.
Remedy: 1. Check error history from "Test: Elec." of self-diagnosis function. 2. Set the number of endurance running cycles to 50 or more from "Life: PF motor" of selfdiagnosis function, and check if "X motor error" occurs. 3. Check "Encoder: PF" from "Test: Encoder" of selfdiagnosis function. 4. Check if Main Power Board normally supplies DC24V. 5. PF motor assembly may be defective. 6. Main board assembly may be defective. - Check connection of following main board assembly connectors. • PF motor cable assembly connector: J107 • PF_ENC assembly connector: J129 • If NG, check connection of main board assembly connector: J129. • Replace PF motor assembly. • Replace main board assembly.
Code: E070
Display: E070 error Y time-out
Description: Time-out condition in head travel distance (Yaxis) during plotter operation. Displayed if carriage does not reach the defined position.
Remedy: 1. Check error history from "Test: Elec." of self-diagnosis function. 2. Move carriage in both directions while the plotter is turned off, and check if there is any position where carriage does not move smoothly. 3. Set the number of endurance running cycles to 50 or more from "Life: CR motor" of selfdiagnosis function, and check if "Y motor error" occurs. - • Clean and lubricate CR rail roller guide. • Check connection of following connectors. Main board: • CR motor assembly connector: J106 • CR cable connector: J110 - J114 CR board: • CR cable connector: J201 - J205 • TF_ENC assembly connector: J210 4. Check if T fence is contaminated or worn out. • If grease or dust collect: Wipe fence with a dry cloth. • If ink deposit presents: Wipe it off with cloth dampened with neutral detergent. • If contamination or deposit is too heavy: Replace T fence. 5. Check "Y Encoder" from "Test: Encoder" of selfdiagnosis function. a) If NG: Check following cable connection. • CR board assembly connector J210 b) Replace following parts. • T fence • CR motor assembly • CR board assembly • CR cable • Replace main board assembly. 6. Main board assembly may be damaged.
Code: E071
Display: E071 error X overcurrent
Description: Overload condition in PF motor (X-axis) during plotter operation.
Remedy: 1. Check error history from "Test: Elec." of self-diagnosis function. 2. Set the number of endurance running cycles to 50 or more from "Life: PF motor" of selfdiagnosis function, and check if "X motor error" occurs. 3. Check "Encoder: PF" from "Test: Encoder" of selfdiagnosis function. 4. Check if Main Power Board normally supplies DC24V. 5. PF motor assembly may be defective. 6. Main board assembly may be defective. - Check connection of following main board assembly connectors. • PF motor cable assembly connector: J107 • PF_ENC assembly connector: J129 • If NG, check connection of main board assembly connector: J129. • Replace PF motor assembly. • Replace main board assembly.
Code: E072
Display: E072 error Y overcurrent
Description: Overload condition in CR motor (Yaxis) during plotter operation.
Remedy: 1. Check error history from "Test: Elec." of self-diagnosis function. 2. Move carriage in both directions while the plotter is turned off, and check if there is any position where carriage does not move smoothly. 3. Set the number of endurance running cycles to 50 or more from "Life: CR motor" of selfdiagnosis function, and check if "Y motor error" occurs. - • Clean and lubricate CR rail roller guide. • Check connection of following connectors. Main board: • CR motor assembly connector: J106 • CR cable connector: J110 - J114 CR board: • CR cable connector: J201 - J205 • TF_ENC assembly connector: J210 4. Check if T fence is contaminated or worn out. • If grease or dust collect: Wipe fence with a dry cloth. • If ink deposit presents: Wipe it off with cloth dampened with neutral detergent. • If contamination or deposit is too heavy: Replace T fence. 5. Check "Y Encoder" from "Test: Encoder" of selfdiagnosis function. a) If NG: Check following cable connection. • CR board assembly connector J210 b) Replace following parts. • T fence • CR motor assembly • CR board assembly • CR cable • Replace main board assembly. 6. Main board assembly may be damaged.