Remedy: 1. Update F/W. 2. Check and clear the parameter. 3. Replace the MAIN PCB with a new one.
Code: 000
Display: SYSTEM HALT (*) 000 : UNNOWN ERR
Description: Unnown error
Remedy: 1. Update F/W. 2. Check and clear the parameter. 3. Replace the MAIN PCB with a new one.
Code: 04
Display: ERROR 04 PARAM ROM
Description: Access Error of the PARAMETER ROM 1.The state that cannot access “FROM” on the MAIN PCB. 2.The state that cannot access “EEPROM” on the Central-IO PCB. 3.Parameter data is abnormal.
Remedy: 1. Replace the FFC and cable located between the HDC PCB and the MAIN PCB. 2. Replace the FFC and cable located between the HDC PCB and the MAIN PCB. 3. Initialize parameter data. 4. Replace the Central-IO PCB with a new one. 5. Replace the MAIN PCB with a new one.
Code: 104
Display: SYSTEM HALT (*) 104 : +35V RECVR
Description: 35 V Power recovery error
Remedy: 1.Replace the DC Power Supply(36V) PCB with a new one. 2. Replace the MAIN PCB with a new one.
Code: 108
Display: ERROR 108 HD CONNECT[12345678]
Description: Head connection error (Head connection can not be confirmed)
Remedy: 1. Check the setting of loading number of the head in the parameter. (System parameter No.41 HEAD NO=3) 2. Check connection between the HDC PCB from the Print Head 3. Replace the HDC PCB with a new one. 4. Replace the Print Head with a new one.
Code: 108
Display: ERROR 108 HD THERMIS[12345678]
Description: Head thermistor (Head temperature can not be measured)
Remedy: 1. Check the setting of loading number of the head in the parameter. (System parameter No.41 HEAD NO=3) 2. Check connection between the HDC PCB from the Print Head 3. Replace the HDC PCB with a new one. 4. Replace the Print Head with a new one.