  • Code: 09
  • Display: FPGA ERROR
  • Description: An error occurred on the control circuit board. (FPGA PDC)
  • Remedy: 1. Replace the main PCB with a new one.
  • Code: 09
  • Display: HDC ERROR (----)
  • Description: An error occurred on the control circuit board. (FPGA HDC)
  • Remedy: 1. Replace the main PCB with a new one.
  • Code: 10
  • Display: COMMAND ERROR
  • Description: The printer received some data other than command data.
  • Remedy: Securely connect the interface cable in position. Use an interface cable conforming to the specifications. 1. When the state is not recovered even if untreated data is cleared, execute the followings. 2. Check the USB cable. (specifications, cable length, etc.) 3. Replace the main PCB with a new one.
  • Code: 11
  • Display: PARAMETER ERROR
  • Description: Any parameter outside the range of acceptable numeric values was received.
  • Remedy: 1. When the state is not recovered even if untreated data is cleared, execute the followings. 2. Check the USB cable. (specifications, cable length, etc.) 3. Replace the main PCB with a new one
  • Code: 12
  • Display: MAINTENANCE COMMAND
  • Description: (This error does not occur on site.)
  • Remedy: 1. When the state is not recovered even if untreated data is cleared, execute the followings. 2. Check the USB cable. (specifications, cable length, etc.) 3. Replace the main PCB with a new one.
  • Code: 120
  • Display: ENVIRONMENT TEMP(LO)
  • Description: The ambient temperature is outside the permissible temperature range (too low).
  • Remedy: Adjust the ambient temperature of the printer. To continue operation without changing the ambient conditions, press the [ENTER] key. Operation under the temperature among the guaranteed operation temperature range is recommended.