Catalog
-
Sign In
-
Contacts
-
Forum
-
Eng
Mimaki JV3-160SP
Error Codes List page 3
|
|
- Code: 21
- Display: ERROR21 I/F NONE
- Description: • The I/F board could not be recognized.
- Remedy: 1) Is the I/F board mounted correctly?
- Code: 23
- Display: ERROR23 HOST I/F
- Description: •A time limit exceeded error occurred in communication between the host computer and the interface board.
- Remedy: 1) Is the cable loose? 2) Has an error occurred on the host computer? 3) Is the application being used running normally?
- Code: 24
- Display: ERROR24 I/F INITIAL
- Description: • The I/F board is in abnormal conditions.
- Remedy: 1) Replace the I/F PCBwith a new one. 2) Replace the main PCB with a new one. 3) Replace the main PCB with a new one.
- Code: 30
- Display: ERROR30 OPERATION
- Description: • Improper operation has been performed.
- Remedy: 1) Indicate the improper operation. 2) Replace a key board. 3) Replace a main PCB.
- Code: 34
- Display: ERROR34 DATA REMAIN
- Description: • Operating condition is tried to be changed when data that has not yet been plotted remains.
- Remedy: 1) This tells that any of the operating conditions cannot be changed if data that have not been plotted remains.
- Code: 40
- Display: ERROR40 MOTOR X
- Description: • The X-axis motor has been overloaded.
- Remedy: 1) Replace X axis motor. 2) Replace a main PCB.