PrintCopy.info service

Mimaki JV3-160SP

Error Codes List page 3

  • Code: 21
  • Display: ERROR21 I/F NONE
  • Description: • The I/F board could not be recognized.
  • Remedy: 1) Is the I/F board mounted correctly?
  • Code: 23
  • Display: ERROR23 HOST I/F
  • Description: •A time limit exceeded error occurred in communication between the host computer and the interface board.
  • Remedy: 1) Is the cable loose? 2) Has an error occurred on the host computer? 3) Is the application being used running normally?
  • Code: 24
  • Display: ERROR24 I/F INITIAL
  • Description: • The I/F board is in abnormal conditions.
  • Remedy: 1) Replace the I/F PCBwith a new one. 2) Replace the main PCB with a new one. 3) Replace the main PCB with a new one.
  • Code: 30
  • Display: ERROR30 OPERATION
  • Description: • Improper operation has been performed.
  • Remedy: 1) Indicate the improper operation. 2) Replace a key board. 3) Replace a main PCB.
  • Code: 34
  • Display: ERROR34 DATA REMAIN
  • Description: • Operating condition is tried to be changed when data that has not yet been plotted remains.
  • Remedy: 1) This tells that any of the operating conditions cannot be changed if data that have not been plotted remains.
  • Code: 40
  • Display: ERROR40 MOTOR X
  • Description: • The X-axis motor has been overloaded.
  • Remedy: 1) Replace X axis motor. 2) Replace a main PCB.