PrintCopy.info service

Mimaki CG60ST

Error Codes List page 1

  • Code: ERR02
  • Display: ERR02 MAIN RAM
  • Description: Malfunction in the main PCB assembly.
  • Remedy: Replace the main PCB assembly.
  • Code: ERR04
  • Display: ERR04 EEPROM
  • Description: Malfunction in the main PCB assembly.
  • Remedy: Initialize the EEPROM as shown below.
    1. Turn the power ON while pressing "Enter" and "End" keys. 2. Take note each value of parameters. 3. Initialize the parameters. 4. If the recorded values of the parameters are normal, set the parameters to the recorded values from the beginning. 5. If the same error occurs even though the parame ters have been set newly, replace the main PCB assembly.
  • Code: ERR06
  • Display: ERR06 BUFFER
  • Description: Malfunction in the main PCB assembly.
  • Remedy: Replace the main PCB assembly.
  • Code: ERR08
  • Display: ERR08 POWER
  • Description: Malfunction in the power supply unit or the main PCB assembly.
  • Remedy: Replace the power supply unit or the main PCB assembly.
  • Code: ERR10
  • Display: ERR10 COMMAND
  • Description: A command, which could not be understood, has been received.
  • Remedy: I. Check the interface conditions. 2. Check whether or not the command is correct, by plotting received ASCII raw data, using the "Dump" function . 3. Check the "Plotter type" of the host computer. 4. Analyze the command using a data monitor.
  • Code: ERR11
  • Display: ERR11 PARAMETER
  • Description: A parameter (exceeding the numerical range), which could not be read, has been received.
  • Remedy: 1. Check the interface conditions. 2. Check whether or not the parameter is correct, by plotting received ASCII raw data, using the "Dump" function. 3. Check the "Plotter type" of the host computer. 4. Analyze the command using a data monitor.
  • Code: ERR12
  • Display: ERR12 DEVICE
  • Description: A device command, which could not be analyzed, has been received.
  • Remedy: I. Check the interface conditions. 2. Check whether or not the device command is correct by plotting received ASCII raw data, using the "Dump" function. 3. Analyze the command using a data monitor.
  • Code: ERR13
  • Display: ERR13 PM OVER
  • Description: The l 8Kbyte polygon buffer overflowed.
  • Remedy: Decompose the polygon data and transmit the data. Refer to the command manual.
Service manual
Error Code
Parts Catalog
Compatibility
Home
New Register Forgot Password?
Send message to us