PrintCopy.info service

Lexmark XM7163

Error Codes List page 1

  • Code: 111.30...111.90
  • Description: 111.30 Printhead ID error 111.31 Printhead no first HSYNC error 111.32 Printhead loss of HSYNC error 111.33 Printhead loss of HSYNC during servo 111.34 Printhead mirror motor loss of lock 111.35 Printhead mirror motor initial lock 111.36 Printhead mirror motor stabilization error 111.37 Page reached input sensor but the mirror motor was not locked 111.38 Page reached input sensor but the printhead startup was not complete 111.90 Printhead video cable not plugged in
  • Remedy: Step 1 Ensure the cables for sockets “MIR MTR” and “VIDEO” on the controller card are properly connected and not damaged. Are the above cables properly connected and undamaged? Go to step 2. Reseat the connections. Go to the next step.
    Step 2 Reset the machine. Does the error continue? Go to step 3. Problem resolved.
    Step 3 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem resolved.
  • Code: 120.10...120.80
  • Description: 120.10 Fuser drive Motor Halls detection error 120.20 Fuser drive Motor took too long to stop 120.30 Fuser drive Motor Unable To Lock (before motor ID) 120.40 Fuser drive motor over.speed error 120.60 Fuser drive motor unable to lock (after motor ID) 120.70 Fuser drive motor out of lock 120.80 Fuser drive motor excessive PWM / over temperature
  • Remedy: Step 1 Ensure the cable for socket “J24” on the controller board is properly connected. Is the above connection properly connected? Go to step 2. Reseat the connections. Go to step 2.
    Step 2 Reset the machine. Does the error continue? Replace the fuser drive motor. See “Fuser drive motor removal”. Go to step 3. Problem resolved
    Step 3 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem resolved.
  • Code: 121.07...121.24
  • Description: 121.07 Fuser has been on for more than allowed after a gap blowout, and the temperature is still too cold 121.08 Fuser was under temperature when page was in fuser 121.20 Fuser undertemp during steady state control 121.22 Fuser did not warm enough to start line voltage detection 121.23 Fuser took too long to heat to line detection temperature 121.24 Fuser never reached fuser detection temperature
  • Remedy: Step 1 Ensure the cable for socket “J24” on the controller board is properly connected. Is the above connection properly connected? Go to step 2. Reseat the connections. Go to step 2.
    Step 2 Reset the machine. Does the error continue? Replace the fuser drive motor. See “Fuser drive motor removal”. Go to step 3. Problem resolved
    Step 3 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem resolved.
  • Code: 121.25
  • Description: After line voltage detection, control did not roll over to steady state control in time
  • Remedy: If the problem remains, replace the controller board.
  • Code: 121.26...121.31
  • Description: 121.25 After line voltage detection, control did not roll over to steady state control in time 121.26 Fuser failed to reach temperature during warm up 121.28 Fuser failed to reach EP warm-up temperature in time 121.29 Fuser failed to reach preheat temperature for motor start during warm up 121.30 Fuser failed to reach printing temperature by the time a page got to the fuser 121.31 Fuser has gotten too hot
  • Remedy: Step 1 Ensure the cable for socket “J24” on the controller board is properly connected. Is the above connection properly connected? Go to step 2. Reseat the connections. Go to step 2.
    Step 2 Reset the machine. Does the error continue? Replace the fuser drive motor. See “Fuser drive motor removal”. Go to step 3. Problem resolved
    Step 3 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem resolved.
  • Code: 121.32...121.49
  • Description: 121.32 Open fuser main thermistor 121.33 Open fuser edge thermistor 121.34 Open fuser backup roll thermistor 121.37 Fuser heated faster than allowed during line voltage detection (115V fuser in 220V machine) 121.48 Fuser Hardware type does not match fuser driver loaded (for example, lamp hardware or belt firmware) 121.49 Fuser backup roll too hot while printing non-wide media
  • Remedy: If the problem remains, replace the fuser