PrintCopy.info service

Konica-Minolta bizhub Pro 951

Error Codes List page 125

  • Code: C-E003
  • Description: Source task error. The ID of the task that sends the message queue is undefined.
  • Causes: Overall control board (OACB)
  • Remedy: 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Reinstall the firmware related to the overall control. 3. Replace OACB.
  • Code: C-E004
  • Description: Receiving event error. The receiving event of the message is undefined.
  • Causes: Overall control board (OACB)
  • Remedy: 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Reinstall the firmware related to the overall control. 3. Replace OACB.
  • Code: C-E005
  • Description: Memory access abnormality.
  • Causes: Overall control board (OACB)
  • Remedy: 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Reinstall the firmware related to the overall control. 3. Replace OACB.
  • Code: C-E006
  • Description: Header readout address abnormality.
  • Causes: Overall control board (OACB)
  • Remedy: 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Reinstall the firmware related to the overall control. 3. Replace OACB.
  • Code: C-E007
  • Description: DRAM memory abnormality. An error is detected in the DRAM memory check at the start.
  • Causes: Overall control board (OACB)
  • Remedy: 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Reinstall the firmware related to the overall control. 3. Replace OACB.