Description: At the start of operation, an error detection signal (solenoid/blowout of clutch ICP) is detected. However, an error detection signal (24V cut off) is not detected.
Causes: Each of the solenoids Each of the clutches DC power supply /2 (DCPS2) Loose connection Wiring harness earth fault ADU drive board (ADUDB)
Code: SC95-01
Description: A specified period of time after the ADU cooling fan /1 (FM10), /2 (FM11) turns on, the F10/11 signal gets into an abnormal condition. This abnormal condition still recurs a specified period of time after it is turned ON again after being turned OFF, and also an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS2) ADU drive board (ADUDB) ADU cooling fan /1 (FM10) ADU cooling fan /2 (FM11) Wiring harness earth fault Loose connection
Code: SC95-03
Description: ADU cooling fan /1 (FM10), /2 (FM11) rotation check. A specified period of time after the FM10, FM11 turns ON, the FM10/11 signal gets into an abnormal condition. This abnormal condition still recurs a specified period of time after it is turned ON again after being turned OFF, and also an error detection signal (24V cut off/blowout of ICP) is not detected.
Causes: DC power supply /2 (DCPS2) ADU drive board (ADUDB) ADU cooling fan /1 (FM10) ADU cooling fan /2 (FM11) Wiring harness earth fault Loose connection