  • Code: C-0303
  • Description: The EM signal shows an abnormal condition when a specified period of time elapses after the paper exit cooling fan (FM8) turns ON. This abnormal condition recurs when a specified period of time elapses after FM8 is turned OFF and then ON again.
  • Causes: Paper exit fan (FM8) Printer control board (PRCB
  • Code: C-0304
  • Description: The EM signal of the ADU cooling fan (FM10) shows an abnormal condition when a specified period of time elapses after FM10 turns ON. This abnormal condition recurs when a specified period of time elapses after FM10 is turned OFF and then ON again.
  • Causes: ADU cooling fan (FM10) ADU drive board (ADUDB) Printer control board (PRCB)
  • Code: C-0305
  • Description: The EM signal shows an abnormal condition when a specified period of time elapses after the paper exit cooling fan /Rr (FM19) turns ON. This abnormal condition recurs when a specified period of time elapses after FM8 is turned OFF and then ON again.
  • Causes: Exhaust fan /Rr (FM19) Printer control board (PRCB)
  • Code: C-1001
  • Description: Serial reception error detection abnormality.
  • Causes: FNS control board (FNSCB) Connector
  • Code: C-1003
  • Description: The communication between FS and PK fails. It shows an abnormal condition after 4 retries.
  • Causes: Relay board (RB) FNS control board (FNSCB) Punch drive board (PDB)
  • Code: C-1004
  • Description: The communication fails when the sub-CPU on the FNS control board (FNSCB) receives data.
  • Causes: FNS control board (FNSCB)