  • Code: CDF50, CDF70, CDFA0
  • Description: ASIC image version failure ASIC image access failure ASIC image error Detection timing Communication error is detected between the MFP board (MFPB) and the CCD board (CCDB).
  • Causes: • MFP board (MFPB) • CCD board (CCDB)
  • Remedy: 1 Check the connector between MFPB and CCDB for proper connection, and correct as necessary. 2 Update the firmware. 3 Replace CCDB 4 Replace MFPB
  • Code: CDF51, CDF71, CDFA1
  • Description: ASIC image version failure (back side) ASIC image access failure (back side) ASIC image error (back side) Detection timing: Communication error is detected between the MFP board (MFPB) and the dual scan image processing board (DSIPB).
  • Causes: • MFP board (MFPB) • Dual scan image processing board (DSIPB)
  • Remedy: 1 Check the connector between MFPB and DSIPB for proper connection, and correct as necessary. 2 Update the firmware. 3 Replace DSIPB 4 Replace MFPB
  • Code: CE001 ... CE007
  • Description: Abnormal message queue Task error Event error Memory access error Header access error DIMM initialize error
  • Causes: MFP board (MFPB)
  • Remedy: 1 Check the connectors on MFPB for proper connection and correct as necessary. 2 Replace MFPB
  • Code: CE002
  • Description: Message and method parameter failure. MFP board (MFPB) is faulty.
  • Causes: • MFP board (MFPB) • Hard disk
  • Remedy: 1 Turn OFF the main power switch and turn it ON again, and conduct the following setting. [Service Mode] -> [System 1] -> [Initialization] -> [Clear All Data]. 2 Format hard disk 3 Replace the hard disk. 4 Replace MFPB
  • Code: CE101
  • Description: Browser finish detected. • The browser is automatically recovered (restarted) after the main body detected that the browser (separate process) has stopped with fault. • When the “Malfunction finish is detected over predetermined number of times” or “the browser task process is except in idle (printing, etc)”.
  • Causes: MFP board (MFPB)
  • Remedy: 1 Check the connectors on MFPB for proper connection and correct as necessary. 2 Replace MFPB.
  • Code: CE201
  • Description: Transmission operation log storage fault. When the transmission log storage failed, it repeats retrial until transmission operation log is stored. The trouble is detected when the retrial failed for predetermined number of times.
  • Causes: MFP board (MFPB)
  • Remedy: 1 Check the connectors on MFPB for proper connection and correct as necessary. 2 Replace MFPB.