  • Code: C1005
  • Description: ZU communication error. When the ZU control board (ZUCB) is receiving data, a communication error is detected.
  • Causes: ZU control board (ZUCB)
  • Remedy: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2 Rewrite the firmware. 3 Replace ZUCB
  • Code: C1080
  • Description: RU communication error When the RU control board (RUCB) is receiving data, a communication error is detected.
  • Causes: RU control board (RUCB)
  • Remedy: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2 Rewrite the firmware. 3 Replace RUCB
  • Code: C1081
  • Description: SD communication error When a communication error is detected between the FS control board (FSCB) and the SD drive board (SDDB).
  • Causes: • SD drive board (SDDB) • FS control board (FSCB)
  • Remedy: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2 Rewrite the firmware. 3 Replace SDDB (SD-511/SD-512) 4 Replace FSCB. (FS-534/FS-535)
  • Code: C1102
  • Description: Main tray up/down motor’s drive malfunction <When FS-534 is installed> • While the exit tray is being lifted, the main tray upper position sensor (PS26/PS27) is not blocked and the main tray upper position detect switch (SW2) is not turned ON, even after the main tray up/down motor (M11) turns by the set number of times. • While the exit tray is being lowered, the main tray full detection sensor (PS29) is not blocked after the set period of time has elapsed after the main tray up/down motor (M11) is turned ON. <When FS-535 is installed> • The main tray upper limit sensor (PS44/PS45) is turned ON even after the set period of time has elapsed while the main tray up/down motor (M5) is energized. • The staple paper exit top surface sensor (PS7) is unblocked even after the set period of time has elapsed while the main tray up/down motor (M5) is energized.
  • Causes: <When FS-534 is installed> • Main tray up/down motor (M11) • Main tray upper position sensor/R (PS26) • Main tray upper position sensor/F (PS27) • Main tray full detection sensor (PS29) • Main tray upper position detect switch (SW2) • FS control board (FSCB) <When FS-535 is installed> • Main tray up/down motor (M5) • Main tray upper limit sensor/in (PS44) • Main tray upper limit sensor/out (PS45) • Staple paper exit top surface sensor (PS7) • FS control board (FSCB)
  • Remedy: When FS-534 is installed: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of M11 for proper drive coupling, and correct as necessary. 3 PS26 I/O check, sensor check FSCB J14<A>-5 (ON) FS-534 2-C 4 PS27 I/O check, sensor check FSCB J14<B>-8 (ON) FS-534 3-C 5 PS29 I/O check, sensor check FSCB J14<A>-8 (ON) FS-534 4-C 6 SW2 operation check FSCB J10-1 to 2 FS-534 8-K 7 M11 operation check FSCB J9<A>-9 to 10 FS-534 10-C to D 8 Replace M11 9 Replace FSCB. When FS-535 is installed: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of M5 for proper drive coupling, and correct as necessary. 3 PS44 I/O check, sensor check FSCB CN24-2 (ON) FS-535 8-L 4 PS45 I/O check, sensor check FSCB CN18-1 to 3 FS-535 13-D 5 PS7 I/O check, sensor check FSCB CN23-15 (ON) FS-535 13-L 6 M5 operation check FSCB CN22-1 to 11 FS-535 5-L 7 Replace M5 8 FSCB ICP1 conduction check 9 Replace FSCB
  • Code: C1103
  • Description: Alignment plate motor/Fr’s malfunction. <When FS-534 is installed> • The alignment plate/F home sensor (PS12) is not unblocked after the set period of time has elapsed after the plate drive starts from the home position. • The alignment plate/F home sensor (PS12) is not blocked after the set period of time has elapsed after the alignment motor/front (M7) is turned ON to return the plate to the home position, • The alignment plate/F does not reach the specified position within the set period of time.<When FS-535 is installed> The alignment plate motor home sensor/Fr (PS17) is not blocked even after the set period of time has elapsed while the Alignment plate motor/Fr (M11) is energized.
  • Causes: <When FS-534 is installed> • Alignment motor/Front (M7) • Alignment plate/F home sensor (PS12) • FS control board (FSCB) <When FS-535 is installed> • Alignment plate motor/Fr (M11) • Alignment plate motor home sensor/F (PS17) • FS control board (FSCB)
  • Remedy: When FS-534 is installed: 1 Check the connector between M7-FSCB J4 for proper connection and correct as necessary. 2 Check the connector of M7 for proper drive coupling, and correct as necessary. 3 Check the connector between PS12-FSCB J4 for proper connection and correct as necessary. 4 PS12 I/O check, sensor check FSCB J4<B>-4 (ON) FS-534 13-C 5 M7 operation check FSCB J4<A>-5 to 8 FS-534 11-C to D 6 Replace M7 7 Replace FSCB. When FS-535 is installed: 1 Check the connector between M11-FSCB CN19 for proper connection and correct as necessary. 2 Check the connector of M11 for proper drive coupling, and correct as necessary. 3 Check the connector between PS17-FSCB CN20 for proper connection and correct as necessary. 4 PS17 I/O check, sensor check FSCB CN20-6 (ON) FS-535 12-D 5 M11 operation check FSCB CN19-1 to 4 FS-535 10-D 6 Replace M11 7 FSCB ICP4 conduction check 8 Replace FSCB
  • Code: C1104
  • Description: Exit roller motor’s malfunction. <When FS-535 is installed> Even after a predetermined period of time has elapsed since the exit roller motor (M4) starts operation, the lock signal is not set to L (turning).
  • Causes: • Exit roller motor (M4) • FS control board (FSCB)
  • Remedy: 1 Check the connector between M4-FSCB CN18 for proper connection and correct as necessary. 2 Check the connector of M4 for proper drive coupling, and correct as necessary. 3 M4 operation check FSCB CN18-4 to 11 FS-535 14-D 4 Replace M4 5 FSCB ICP14 conduction check 6 Replace FSCB