KIP C7800
Error Codes List page 10
|
- Code: 0D-07, 0D-08
- Description: IPS Cooling Fan Error
- Causes: 0D-07: IPS Cooling Fan 1 0D-08: IPS Cooling Fan 2
- Remedy: Harness 1 Is the wiring OK between the followings? Cooling Fan (FM10, FM11) Fuser Drive PCB (PW12556) No Correct it.
IPS Cooling Fan 2 Can the problem be fixed by replacing the IPS Cooling Fan? Yes OK
Fuser Drive PCB (PW12556) 3 Can the problem be fixed by replacing the Fuser Drive PCB? Yes OK
Main Control PCB (PW12520) 4 Can the problem be fixed by replacing the Main Control PCB? Yes OK
- Code: 0D-09, 0D-0A
- Description: Fuser Blower Error
- Causes: 0D-09: Fuser Blower 1 0D-0A: Fuser Blower 2
- Remedy: Harness 1 Is the wiring OK between the followings? Fuser Blower (BL1, BL2) Fuser Drive PCB (PW12556) No Correct it.
Fuser Blower 2 Can the problem be fixed by replacing the Fuser Blower? Yes OK
Fuser Drive PCB (PW12556) 3 Can the problem be fixed by replacing the Fuser Drive PCB? Yes OK
Main Control PCB (PW12520) 4 Can the problem be fixed by replacing the Main Control PCB? Yes OK
- Code: J-0101
- Description: Roll Deck 1 Jam: Power ON
- Causes:
- Remedy: 1 Have you removed all jammed sheets in the media path? No Clear the media path.
Harness 2 Is the wiring OK between the followings? Media Sensor (PH11) Deck Drive PCB (PW12557A) Media Sensor (PH44) Dev Drive PCB (PW12555C) No Correct it
Media Sensor (PH11, PH44) 3 Can the problem be fixed by replacing the sensor? Yes OK
Deck Drive PCB (PW12557A) Dev Drive PCB (PW12555C) 4 Can the problem be fixed by replacing the PCB? Yes OK
Main Control PCB (PW12520) 5 Can the problem be fixed by replacing the Main Control PCB? Yes OK
- Code: J-0102
- Description: Roll Deck 2 Jam: Power ON
- Causes:
- Remedy: 1 Have you removed all jammed sheets in the media path? No Clear the media path.
Harness 2 Is the wiring OK between the followings? Media Sensor (PH16) Deck Drive PCB (PW12557B) Media Sensor (PH54) Dev Drive PCB (PW12555D) No Correct it
Media Sensor (PH16, PH54) 3 Can the problem be fixed by replacing the sensor? Yes OK
Deck Drive PCB (PW12557B) Dev Drive PCB (PW12555D) 4 Can the problem be fixed by replacing the PCB? Yes OK
Main Control PCB (PW12520) 5 Can the problem be fixed by replacing the Main Control PCB? Yes OK
- Code: J-0103
- Description: Roll Deck 3 Jam: Power ON
- Causes:
- Remedy: 1 Have you removed all jammed sheets in the media path? No Clear the media path.
Harness 2 Is the wiring OK between the followings? Media Sensor (PH21) Media Sensor (PH22) Deck Drive PCB (PW12557C) No Correct it
Media Sensor (PH21, PH22) 3 Can the problem be fixed by replacing the sensor? Yes OK
Deck Drive PCB (PW12557C) 4 Can the problem be fixed by replacing the PCB? Yes OK
Main Control PCB (PW12520) 5 Can the problem be fixed by replacing the Main Control PCB? Yes OK
- Code: J-0105
- Description: Bypass Feeder Jam: Power ON
- Causes:
- Remedy: 1 Have you removed all jammed sheets in the media path? No Clear the media path.
Harness 2 Is the wiring OK between Bypass Start Sensor (PH38) and Dev Drive PCB (PW12555B)? No Correct it
Bypass Start Sensor (PH38) 3 Can the problem be fixed by replacing the sensor? Yes OK
Dev Drive PCB (PW12555B) 4 Can the problem be fixed by replacing the PCB? Yes OK
Main Control PCB (PW12520) 5 Can the problem be fixed by replacing the Main Control PCB? Yes OK