  • Code: E-0732, E-1842
  • Description: Abnormal Output of Separation Plus Charger at 2nd Transfer
  • Causes: The signal from FPGA on PW13555 (00525: 2Tr Separation St(+)) shows "H" for longer than 20msec.
  • Remedy: Error Mask Mode No. 00703 Tr2 Sep Minus Error Error Mask Mode No. 00704 Tr2 Sep Plus Error
    PW13556 1 Replacing PW13556 recovers the error condition. Yes OK
    PW13555 2 Replacing PW13555 recovers the error condition. Yes OK Main Control PCB (PW13520) 3 Replacing PW13520 PCB recovers the error condition. Yes OK
  • Code: E-0733, E-1843
  • Description: Standard Current Adjustment of 2nd Transfer Error
  • Causes: Reference voltage for 2nd Transfer Current detection is failed to adjust to target voltage on PW13555.
  • Remedy: Error Mask Mode No. 00705 Tr2 Adjust Error Backup Data Mode No. 00718 Tr2 Auto Adjustment
    PW13556 1 Replacing PW13556 recovers the error condition. Yes OK PW13555 2 Replacing PW13555 recovers the error condition. Yes OK Main Control PCB (PW13520) 3 Replacing PW13520 PCB recovers the error condition. Yes OK
  • Code: E-0735
  • Description: Abnormal Output of Separation Charger
  • Causes: Internal detection circuit for the HV of Separation Needles detects some abnormality
  • Remedy: Electric continuity 1 Using a multi-meter check the electric continuity between TB_SEP (on PW13556_02) and GND. Is there an electric continuity? Yes As the high voltage seems to be leaking, check the harness, Separation Discharge Needles, and concerning parts and find the point of leaking, No Go to 2. TB_SEP connector 2 Turn off the printer, plug out the TB_SEP connector on the PW13556_02, and turn the printer back on. Does the E-0735 error appear again? Yes If the E-0735 error still appears, go to 3. No In case the E-0735 error does not appear but any other high voltage error appears, go to the troubleshooting section of indicated error. PW15556_02 Secondary Transfer PCB Assy 3 Does the error disappears if you replace the PW15556_02 PCB with another one? Yes OK No Go to 4. Other factors 4 If the E-0735 error still appears, plug out the connector TB_SEP (on PW13556_02), and print out the test pattern No.18 from the Maintenance GUI. Does the printout have any abnormal image? Yes Any high voltage has some abnormality such as leaking and causing the abnormal image. Check all high voltage items and find the abnormality. No Check the Separation Discharge Needle as it may be having some abnormality such as deformation and etc. Also please try to replace the Separation Discharge Needle with another one. And just in case, check the HV harness to the Separation Discharge Needle.
  • Code: E-0900, E-2304
  • Description: Fuser Low-Temp Error
  • Causes: 1. The fuser temperature failed to reach 50 deg C within 6 minutes in case the fuser temperature at power on was below 50 deg C. 2. The fuser temperature failed to reach Idling Temperature (Backup Data 02000: Idle Temp) within 6 minutes since it has passed 50 deg C. 3. The fuser temperatures (Fuser Temp 1 and Fuser Temp 2) failed to reach Ready Temperature (Backup Data 02001: Ready Temp 1 / 02002: Ready Temp 2 respectively) within 6 minutes since those have passed the Idling Temperature. 4. The fuser temperature failed to fall to Ready Temperature within 6 minutes in case the fuser temperature at power on was above the Ready Temperature. 5. The fuser temperature fell down below 100 deg C while printer status is Stand By. 6. The fuser temperature fell down below 70 deg C while printer status is Warm Sleep.
  • Remedy: Output Check Mode No. 00600 SSR1 (H1: Center) Output Check Mode No. 00601 SSR2 (H2: Side) Information Mode No. 00013 Detection Temp1 Information Mode No. 00014 Detection Temp2 Check if relevant “IR Lamp” is possible to operate in Output Check Mode.
    1. In case the Item is Inoperative. Wiring Harness 1 Any of following connectors is unplugged. J224 on PW13520, TB1 to TB4 on SSR1/SSR2, TB101 to TB108 on AC Terminal PW14210, TB0 to TB8 on RY2. Yes Plug the Connector. Inter Lock Circuit 2 Voltage between RY2-0 and RY2-1 is 10 to 12V DC. (RY2-0 and Frame GND is 10 to 12V DC, RY2-1 and Frame GND is 0V DC) No Check Output of each DC Power Supply is OK. Check Inter Lock circuit is OK or replace PW13555 RY2 3 Voltage between RY2-4 and RY2-8 is 200V AC. No Replace RY2 IR Lamp (H1 H2) 4 Unplug the machine. Unplug IR Lamp. Read resistance between IR Lamp side by side connectors. There is readable resistance read by Multi Meter. No Replace IR Lamp. SSR1 5 Run Output Check No. 00600 SSR1. IR Lamp (H1: Center) is lighting while voltage between SSR1-3 and SSR1-4 is 24V DC. (SSR1-3 and F-GND is 24V DC, SSR1-4 and F-GND is 0V DC) No In Case SSR1-3 and SSR1-4 is 24V DC, replace SSR1. In Case SSR1-3 and F-GND is not 24V DC check DCP. In Case SSR1-4 and F-GND is not 0V DC replace PW13520. SSR2 6 Run Output Check No. 00601 SSR2. IR Lamp (H2: Side) is lighting while voltage between SSR2-3 and SSR2-4 is 24V DC. (SSR2-3 and F-GND is 24V DC, SSR2-4 and F-GND is 0V DC) No In Case SSR2-3 and SSR2-4 is 24V DC, replace SSR2. In Case SSR2-3 and F-GND is not 24V DC check DCP. In Case SSR2-4 and F-GND is not 0V DC replace PW13520. PW13555 7 Replacing PW13555 PCB recovers the error condition. Yes OK Main Control PCB (PW13520) 8 Replacing PW13520 PCB recovers the error condition. Yes OK
    2. In case the Item is Operative. Wiring Harness 1 All of the following connectors are surely connected. J559 on PW13555, J700 on Fuser Unit, J707 J708 on Thermistor No Plug the Connector. Thermistor (TH1 TH2) 2 Check the detecting temperature from Information Mode No. 00013 and No. 00014. It is possible to observe the temperature rise up while IR Lamp light. No Check Thermistor mounting conditions. Or replace relevant Thermistor. PW13555 3 Replacing PW13555 PCB recovers the error condition. Yes OK Main Control PCB (PW13520) 4 Replacing PW13520 PCB recovers the error condition. Yes OK
  • Code: E-0902, E-2306
  • Description: Out of Web Error
  • Causes: 1500 liner meter media is printed since Web Near End has been detected.
  • Remedy: Information Mode No. 00607 Web End Sensor (“H” = Web End)
    Sensor Detection 1 Web End Sensor is detecting “H” = Web End condition. Yes To make Web End Sensor detecting Web Remaining condition (status “L”) change and remount a new Web correctly. Sensor Actuator 2 Sensor is still detecting “H” Yes Verify the actuator for Web End Sensor is cutting Web End Sensor when assembling Web Unit correctly. (should be detecting “L” with correctly assembling condition) Wiring Harness 3 Verify Web End Sensor detects “H” while disassembling Web Unit. No Check J558 on PW13555, J700 on Fuser Unit and J709 on Web End Sensor are surely connected. Web End Sensor (PH68) 4 Sensor is still detecting “L” while disassembling Web Unit. Yes Replace Web End Sensor. (should be detecting “H” with disassembling condition) Clear / Reset 5 Clearing No. 0003 Clear Web Info in Clear/Reset Mode recovers the Error condition. Yes OK PW13555 6 Replacing PW13555 PCB recovers the error condition. Yes OK Main Control PCB (PW13520) 7 Replacing PW13520 PCB recovers the error condition. Yes OK
  • Code: E-0904, E-2308
  • Description: Fuser Over-Temp at Thermistor 1 Error
  • Causes: 1. Thermistor 1 detects that the Fuser Temperature is over 200 deg C. 2. The signal from FPGA on PW13555 (Fuser Thermistor 1 High-temperature Abnormality) shows "H" for longer than 1 second.
  • Remedy: Output Check Mode No. 00600 SSR1 (H1: Center) Output Check Mode No. 00601 SSR2 (H2: Side) Information Mode No. 00013 Detection Temp1 Information Mode No. 00014 Detection Temp2 Check if relevant “IR Lamp” is possible to operate in Output Check Mode.
    1. In case the Item is Inoperative. (IR Lamp lights but not turn OFF) Wiring Harness 1 Following connectors and wires are OK. J224 on PW13520, TB1 to TB4 on SSR1/SSR2, TB101 to TB108 on AC Terminal PW14210, TB0 to TB8 on RY2. No Correct SSR1 2 If IR Lamp (H1: Center) is lighting while Output Check No. 00600 SSR1 status is “Inactive”. Please check voltage between SSR1-3 and SSR1-4. (Also between SSR1-4 and F-GND.) Yes In Case SSR1-3 and SSR1-4 is 0V DC, replace SSR1. In Case SSR1-4 and F-GND is 0V DC replace PW13520 or check the wiring. SSR2 3 If IR Lamp (H2: Center) is lighting while Output Check No. 00601 SSR2 status is “Inactive”. Please check voltage between SSR2-3 and SSR2-4. (Also between SSR2-4 and F-GND.) No In Case SSR2-3 and SSR2-4 is 0V DC, replace SSR2. In Case SSR2-4 and F-GND is 0V DC replace PW13520 or check the wiring. PW13555 4 Replacing PW13555 PCB recovers the error condition. Yes OK Main Control PCB (PW13520) 5 Replacing PW13520 PCB recovers the error condition. Yes OK
    2. In case the Item is Operative. Wiring Harness 1 All of the following connectors are surely connected. J559 on PW13555, J700 on Fuser Unit, J707 J708 on Thermistor No Plug the Connector. Thermistor (TH1 TH2) 2 Check the detecting temperature from Information Mode No. 00013 and No. 00014. It is possible to observe the temperature rise up while IR Lamp light. No Check Thermistor mounting conditions. Or replace relevant Thermistor. PW13555 3 Replacing PW13555 PCB recovers the error condition. Yes OK Main Control PCB (PW13520) 4 Replacing PW13520 PCB recovers the error condition. Yes OK