  • Code: E-0706, E-1798
  • Description: Registration Motor 2 Error
  • Causes: The signal from FPGA on PW13555 (00521: Registration Motor2 Status) shows "H" for longer than 1 second. (“H”= abnormal condition is detected on motor driver IC)
  • Remedy: Error Mask Mode No. 00500 Regist Motor1 Error Error Mask Mode No. 00501 Regist Motor2 Error Error Mask Mode No. 00502 Regist Motor3 Error Output Check Mode No. 00500 Regist Motor1 Output Check Mode No. 00501 Regist Motor2 Output Check Mode No. 00502 Regist Motor3 Check if “Regist Motor” is possible to operate in Output Check Mode.
    1. In case the Item is Inoperative. 1 The operation “Main Switch Off/On on10 minutes later” recovers the error condition. Yes Go to Case 2 Wiring Harness 2 Unplugging J563 on PW13555 recovers the error condition. Yes Check the motor harness damage. Regist Motor PF1 MTR (M4-1) PF2 MTR (M4-2) PF3 MTR (M4-3) 3 Replacing Regist Motor (M4-x) recovers the error condition. Yes OK PW13555 4 Replacing PW13555 PCB recovers the error condition. Yes OK Main Control PCB (PW13520) 5 Replacing PW13520 PCB recovers the error condition. Yes OK
    2. In case the Item is Operative. 1 Several test prints reproduces the error again No OK Regist Motor PF1 MTR (M4-1) PF2 MTR (M4-2) PF3 MTR (M4-3) 2 Replacing Regist Motor (M4-x) recovers the error condition. Yes OK PW13555 3 Replacing PW13555 PCB recovers the error condition. Yes OK Main Control PCB (PW13520) 4 Replacing PW13520 PCB recovers the error condition. Yes OK
  • Code: E-0707, E-1799
  • Description: Registration Motor 3 Error
  • Causes: The signal from FPGA on PW13555 (00522: Registration Motor3 Status) shows "H" for longer than 1 second. (“H”= abnormal condition is detected on motor driver IC)
  • Remedy: Error Mask Mode No. 00500 Regist Motor1 Error Error Mask Mode No. 00501 Regist Motor2 Error Error Mask Mode No. 00502 Regist Motor3 Error Output Check Mode No. 00500 Regist Motor1 Output Check Mode No. 00501 Regist Motor2 Output Check Mode No. 00502 Regist Motor3 Check if “Regist Motor” is possible to operate in Output Check Mode.
    1. In case the Item is Inoperative. 1 The operation “Main Switch Off/On on10 minutes later” recovers the error condition. Yes Go to Case 2 Wiring Harness 2 Unplugging J563 on PW13555 recovers the error condition. Yes Check the motor harness damage. Regist Motor PF1 MTR (M4-1) PF2 MTR (M4-2) PF3 MTR (M4-3) 3 Replacing Regist Motor (M4-x) recovers the error condition. Yes OK PW13555 4 Replacing PW13555 PCB recovers the error condition. Yes OK Main Control PCB (PW13520) 5 Replacing PW13520 PCB recovers the error condition. Yes OK
    2. In case the Item is Operative. 1 Several test prints reproduces the error again No OK Regist Motor PF1 MTR (M4-1) PF2 MTR (M4-2) PF3 MTR (M4-3) 2 Replacing Regist Motor (M4-x) recovers the error condition. Yes OK PW13555 3 Replacing PW13555 PCB recovers the error condition. Yes OK Main Control PCB (PW13520) 4 Replacing PW13520 PCB recovers the error condition. Yes OK
  • Code: E-0712, E-1810
  • Description: Transfer Roller set Motor 2 Error
  • Causes: The signal from PW13555 (00511: Tr2 RollerSet Sen) does not show Set Status (H to L) or Released Status (L to H) within 10 seconds since (00512: Tr2 SeparateMotor) starts operating.
  • Remedy: Error Mask Mode No. 00505 Tr2 Set MT Error Output Check Mode No. 00512 Tr2 Separate Motor Input Check Mode No. 00511 Tr2 RollerSet Sen Check if relevant “Transfer Roller Set Motor” is possible to operate in Output Check Mode.
    1. In case the Item is Inoperative. Wiring Harness for Motors 1 Any of following connectors is unplugged. J563 on PW13555, J1900 on Paper Feed Unit, J901 on 2TR SET MOTOR. Yes Plug the Connector. 2Tr Set Motor (M5) 2 Replacing Tr2 Set Motor (M5) recovers the error condition. Yes OK PW13555 3 Replacing PW13555 PCB recovers the error condition. Yes OK Main Control PCB (PW13520) 4 Replacing PW13520 PCB recovers the error condition. Yes OK
    2. In case the Item is Operative. Wiring Harness for Sensors 1 All of the following connectors are surely connected. J563 on PW13555, J1900 on Paper Feed Unit, J902 on 2TR SET SENSOR No Plug the Connector. Tr2 Roller Set Sensor (PH61) 2 Transfer Roller Set Sensor Signals are detected correctly. Sensor Status -Set status (H to L) -Released status (L to H) No Replace relevant Tr2 Roller Set Sensor. PW13555 3 Replacing PW13555 PCB recovers the error condition. Yes OK Main Control PCB (PW13520) 4 Replacing PW13520 PCB recovers the error condition. Yes OK
  • Code: E-0721, E-1825
  • Description: KTS Belt Skew Error (Left Side)
  • Causes: The signal from FPGA on PW13555 (00512: Belt Skew Sensor L) shows "H" for longer than 100msec.
  • Remedy: Error Mask Mode No. 00506 Belt Skew Error (L) Error Mask Mode No. 00507 Belt Skew Error (R) Input Check Mode No. 00512 Belt Skew Sensor L Input Check Mode No. 00513 Belt Skew Sensor R
    1. In case the Sensor works correctly. Belt Position 1 Relevant Sensor is detecting side edge of KTS Belt. Yes No Fix the Belt Position. Go to Case 2. Skew Adjustment 2 Several test prints reproduces the error condition again. Yes No Need mechanical Skew Adjustment. OK
    2. In case the Sensor works incorrectly. Sensor malfunction 1 Cleaning sensor detecting point recovers the error condition. Yes OK Wiring Harness for Sensors 2 All of the following connectors are surely connected. J568 on PW13555, J1009 on Belt Unit, J1013 J1014 on Belt Skew Sensors. No Plug the Connector. KTS Belt Skew Sensor (PH57 PH58) 3 KTS Belt Skew Sensor detects correct status. “H” = Abnormal. No Replace Skew Sensor. PW13555 4 Replacing PW13555 PCB recovers the error condition. Yes OK Main Control PCB (PW13520) 5 Replacing PW13520 PCB recovers the error condition. Yes OK
  • Code: E-0722, E-1826
  • Description: KTS Belt Skew Error (Right Side)
  • Causes: The signal from FPGA on PW13555 (00513: Belt Skew Sensor R) shows "H" for longer than 100msec.
  • Remedy: Error Mask Mode No. 00506 Belt Skew Error (L) Error Mask Mode No. 00507 Belt Skew Error (R) Input Check Mode No. 00512 Belt Skew Sensor L Input Check Mode No. 00513 Belt Skew Sensor R
    1. In case the Sensor works correctly. Belt Position 1 Relevant Sensor is detecting side edge of KTS Belt. Yes No Fix the Belt Position. Go to Case 2. Skew Adjustment 2 Several test prints reproduces the error condition again. Yes No Need mechanical Skew Adjustment. OK
    2. In case the Sensor works incorrectly. Sensor malfunction 1 Cleaning sensor detecting point recovers the error condition. Yes OK Wiring Harness for Sensors 2 All of the following connectors are surely connected. J568 on PW13555, J1009 on Belt Unit, J1013 J1014 on Belt Skew Sensors. No Plug the Connector. KTS Belt Skew Sensor (PH57 PH58) 3 KTS Belt Skew Sensor detects correct status. “H” = Abnormal. No Replace Skew Sensor. PW13555 4 Replacing PW13555 PCB recovers the error condition. Yes OK Main Control PCB (PW13520) 5 Replacing PW13520 PCB recovers the error condition. Yes OK
  • Code: E-0731, E-1841
  • Description: Abnormal Output of Separation Minus Charge at 2nd Transfer
  • Causes: The signal from FPGA on PW13555 (00524: 2Tr Separation St(-)) shows "H" for longer than 20msec.
  • Remedy: Error Mask Mode No. 00703 Tr2 Sep Minus Error Error Mask Mode No. 00704 Tr2 Sep Plus Error
    PW13556 1 Replacing PW13556 recovers the error condition. Yes OK
    PW13555 2 Replacing PW13555 recovers the error condition. Yes OK Main Control PCB (PW13520) 3 Replacing PW13520 PCB recovers the error condition. Yes OK