PrintCopy.info service

HP DesignJet 9000s

Error Codes List page 8

  • Code: H05
  • Description: Center Heater Temperature Error
    Temperature read by the Center Heater is abnormal (lower than -10C or higher than 70C).
  • Remedy: • Make sure that the Heater Relay Assembly is connected correctly to the Center Platen. • Replace the Heater Relay Assembly. • Replace the Center Platen.
  • Code: H06
  • Description: Front Heater Time-out Error
    The temperature of the Front Heater does not reach the preset temperature even after 15 minutes.
  • Remedy: • Make sure that the Voltage alternation switch located at the back of the Printer is set correctly to the AC voltage being used. • Make sure that the Fuse (F2) on the Heater Relay Assembly has not blown. If the fuse has blown, replace it. • Make sure that the Heater Board is connected correctly to the Relay Board via the Relay Cable. • Make sure that the Heater Relay Assembly is connected correctly to the Front Heater. • Replace the Heater Relay Assembly. • Replace the Front Heater.
  • Code: H07
  • Description: Rear Heater Time-out Error
    The temperature of the Rear Heater does not reach the preset temperature even after 15 minutes.
  • Remedy: • Make sure that the Voltage alternation switch located at the back of the Printer is set correctly to the AC voltage being used. • Make sure that the Fuse (F2) on the Heater Relay Assembly has not blown. If the fuse has blown, replace it. • Make sure that the Heater Board is connected correctly to the Relay Board via the Relay Cable. • Make sure that the Heater Relay Assembly is connected correctly to the Rear Heater. • Replace the Heater Relay Assembly. • Replace the Rear Heater.
  • Code: H08
  • Description: Center Heater Time-out Error
    The temperature of the Center Heater does not reach the preset temperature even after 15 minutes.
  • Remedy: • Make sure that the Voltage alternation switch located at the back of the Printer is set correctly to the AC voltage being used. • Make sure that the Fuse (F2) on the Heater Relay Assembly has not blown. If the fuse has blown, replace it. • Make sure that the Heater Board is connected correctly to the Relay Board via the Relay Cable. • Make sure that the Heater Relay Assembly is connected correctly to the Center Platen. • Replace the Heater Relay Assembly. • Replace the Center Platen Heater.
  • Code: H09
  • Description: Operation Panel Switch Error
    The specified switch is not pressed for 30 seconds or more when the diagnostics that verifies the switch action is executed.
  • Remedy: • Replace the Heater Relay Assembly.
  • Code: H10
  • Description: Zero Cross Error
    This error occurs when the diagnostics for the AC Relay is executed.
  • Remedy: • Make sure that the Heater Board is connected correctly to the relays on the Heater Block Assembly • Make sure that the Heater Board is connected correctly to the Relay Board via the Relay Cable. • Replace the Heater Relay Assembly.