Description: ASIC Communication Error (Write) Failed to connect (write) the Ink Holder Board.
Causes: • Ink Holder Cable (FFC) abnormality (connection, broken) • Ink Holder Board (CSIC Contact Module) is damaged • Main Board broken • Sub Board B broken Parts/Components to be checked 1. Ink Holder Cable (FFC) 2. Ink Holder 3. Main Board 4. Sub Board B
Remedy: 1 Check the Ink Holder Cable (FFC) connection • Check the Ink Holder Cable (FFC) connection state. If there is any abnormality, connect it again. Does the product recover from the error? Y: End N: Go to step 2 2 Replace the Ink Holder Cable (FFC) Does the product recover from the error? Y: End N: Go to step 3 3 Replace the Ink Holder Does the product recover from the error? Y: End N: Go to step 4 4 Replace the Main Board Does the product recover from the error? Y: End N: Go to step 5 5 Replace the Sub Board B Does the product recover from the error? Y: End N: Escalate to person in charge
Code: 004000
Description: Inspection Mode Printdata Receive Error Normal printing in Inspection mode is detected.
Causes: • Normal printing cannot be performed in Inspection mode.
Remedy: 1 Print in normal mode Does the product recover from the error? Y: End N: Escalate to person in charg
Code: 202620
Description: WIFI Board Failure Error WiFi Board failure is detected.
Causes: • WIFI Board cable abnormality (connection, broken) • WIFI Board failure Parts/Components to be checked 1. WIFI Board
Remedy: 1 Check the WIFI Board cable connection • Check the WIFI Board connection state. If there is any abnormality, connect it again. Does the product recover from the error? Y: End N: Go to step 2 2 Replace the WIFI Board Does the product recover from the error? Y: End N: Escalate to person in charge
Code: 203002
Description: Optical Touch Panel Failure Error Panel failure is detected.
Causes: • Panel FFC abnormality (connection, broken) • Panel failure Parts/Components to be checked 1. Panel 2. Replace the Panel FFC
Remedy: 1 Check the Panel FFC connection • Check the FFC connection state. If there is any abnormality, connect it again. Does the product recover from the error? Y: End N: Go to step 2 2 Replace the Panel Does the product recover from the error? Y: End N: Go to step 3 3 Replace the Panel FFC Does the product recover from the error? Y: End N: Escalate to person in charge