  • Code: 1101
  • Description: CR life error
  • Causes: The maintenance counter for the Ink Supply Tube exceeded the threshold value. (CR scan pass counter has reached the specified value (six million passes)).
  • Remedy: Replace the following parts and reset the counter of the CR Motor. • Ink Tubes • CR Motor • Head FFC • Oil pad
  • Code: 1125
  • Description: CR HP detection error
  • Causes: The CR Unit cannot track the Home position to set the CR origin. • False origin detection due to paper jam or the like • Misreading of CR Scale • CR Lock is damaged.
  • Remedy: 1. Re-install the CR Encoder. 2. Clean the CR Scale with ethanol. 3. Replace the CR Scale. 4. Replace the IS Unit.
  • Code: 1138
  • Description: CR Motor over current error
  • Causes: 1. Connection failure of the CR Motor or the CR Encoder. 2. Detects accumulatively more than the specified number of times that the electric current which flows when driving the motor is irregularly large. • Irregular load • CR Encoder failure • CR Motor failure
  • Remedy: 1. Replace the CR Encoder. 2. Replace the CR Motor. 3. If the printer does not recover from the error, it may be caused by irregular load of the CR Mechanism. Replace the Printer Mechanism.
  • Code: 113A
  • Description: CR Motor overload error
  • Causes: The electric current flowing when driving the motor is irregularly large. • CR Encoder cable is damaged. • CR Motor cable is damaged. • Irregular load • CR Encoder failure • CR Motor failure
  • Remedy: 1. Re-install the CR Unit. 2. Replace the CR Encoder. 3. Replace the CR Motor.
  • Code: 113B
  • Description: CR Motor over speed error
  • Causes: Detects that it is being driven at an irregularly faster speed than the specified value just before stopping. • Irregular load • CR Encoder failure • SUB Board is damaged. • CR Motor driver failure
  • Remedy: 1. Replace the CR Encoder. 2. Replace the SUB-B Board. 3. Replace the Main Board.
  • Code: 113C
  • Description: CR Motor reversing error
  • Causes: Detects accumulatively more than the specified number of times that it is being driven in the opposite direction to the specified driving direction. • The polarity of CR Encoder cable is opposite. • The polarity of CR Motor cable is opposite. • Slipping of the teeth of CR Timing Belt • CR Encoder failure
  • Remedy: 1. Adjust the tension of the CR Timing Belt. 2. Replace the CR Encoder.