Description: Ink Tubes life error The Ink Tubes have reached the end of their service life. (CR scan pass counter has reached a predetermined limit.)
Remedy: Replace the Ink Tubes and reset the counter .
Code: 1125
Description: CR HP detection error The CR Unit does not respond to the CR HP Sensor, or the sensor failed to detect the home position. • CR HP Sensor failure • False detection of the home due to paper jam or any other obstacle • Misreading of the CR Scale • CR Lock is damaged.
Remedy: 1. Replace the CR Encoder. 2. Re-install the CR Encoder. If it is faulty, replace it. 3. Clean the CR Scale using ethanol. 4. Replace the CR Scale. 5. Replace the CR Lock .
Code: 1138
Description: CR Motor overcurrent error 1. Connection failure of the CR Motor or the CR Encoder. 2. The number of occurrences of overcurrent to the CR Motor has reached a predetermined limit. • Irregular load • CR Encoder failure • CR Motor failure
Remedy: 1. Replace the CR Encoder. 2. Replace the CR Motor.
Code: 1139
Description: CR Motor oscillation error The control terminal (Vre terminal) of the CR Motor driver has shorted out.
Remedy: 1. Remove the foreign material. 2. If the error still occurs, replace the Main Board.
Code: 113A
Description: CR Motor overload error Overcurrent to the CR Motor was detected. • CR Encoder cable is damaged. • CR Motor cable is damaged. • Irregular load • CR Encoder failure • CR Motor failure
Remedy: 1. Re-install the CR Unit. 2. Replace the CR Encoder. 3. Replace the CR Motor.
Code: 113B
Description: CR Motor over speed error The CR Motor was driven at a speed faster than a predetermined one during deceleration. • Irregular load • CR Encoder failure • SUB Board is damaged. • CR Motor driver failure
Remedy: 1. Replace the CR Encoder. 2. Replace the SUB Board. 3. Replace the Main Board.