Causes: The Ink Tubes have reached the end of their service life. (CR scan pass counter has reached a predetermined limit.)
Remedy: Replace the Ink Tubes and reset the counter.
Code: 1125
Description: CR HP detection error
Causes: The CR Unit does not respond to the CR HP Sensor, or the sensor failed to detect the home position. • CR HP Sensor failure • False detection of the home due to paper jam or any other obstacle • Misreading of the CR Scale • CR Lock is damaged.
Remedy: 1. Is the CR HP Sensor out of order? Does the light shielding plate react to the sensor? 2. Is there any paper jammed inside the printer? 3. Does the CR Scale have any scratches or dirt? 4. Does the CR Encoder work properly? Check it using the Service Program. 5. Does the CR Lock function normally? 1. Replace the CR Encoder. 2. Re-install the CR Encoder. If it is faulty, replace it. 3. Clean the CR Scale using ethanol. 4. Replace the CR Scale. 5. Replace the CR Lock (Pump Cap Unit).
Code: 1138
Description: CR Motor overcurrent error
Causes: 1. Connection failure of the CR Motor or the CR Encoder. 2. Number of over current is reached limit of the CR motor • Irregular load • CR Encoder failure • CR Motor failure
Remedy: 1. Is there any problems such as damaged cable in the connections below? • CR HP Sensor • CR Encoder to SUB Board (CN102) • CR Motor to SUB-M Board (CN1) 2. Does the CR Encoder work properly? Check it using the Service Program. 1. Replace the CR HP Sensor. 2. Replace the CR Encoder. 3. Replace the CR Motor.
Code: 1139
Description: CR Motor oscillation error
Causes: The control terminal (Vre terminal) of the CR Motor driver has shorted out.
Remedy: 1. Is the CR Motor driver on the Main Board damaged? 2. Is there any foreign materials around the CR Motor driver? 1. Remove the foreign material. 2. If the error still occurs, replace the Main Board.
Code: 113A
Description: CR Motor overload error
Causes: Overcurrent to the CR Motor was detected. • CR Encoder cable is damaged. • CR Motor cable is damaged. • Irregular load • CR Encoder failure • CR Motor failure
Remedy: 1. Is the CR Unit being attached correctly? 2. Is there any foreign materials on the CR Unit drive path? 3. Is there any problems such as damaged cable in the connections below? • CR Encoder to SUB Board (CN102) • CR Motor to SUB-M Board (CN1) 4. Does the CR Encoder work properly? Check it using the Service Program. 1. Re-install the CR Unit. 2. Replace the CR Encoder. 3. Replace the CR Motor.
Code: 113B
Description: CR Motor over speed error
Causes: The CR Motor was driven at a speed faster than a predetermined one during deceleration. • Irregular load • CR Encoder failure • SUB Board is damaged. • CR Motor driver failure
Remedy: Does the CR Encoder work properly? Check it using the Service Program. 1. Replace the CR Encoder. 2. Replace the SUB Board. 3. Replace the Main Board.