Description: Communication with the tape cluster is not performed normally Communication between the main PCB and the tape cluster PCB is defective.
Causes: The tape cluster PCB unit is defective. The main PCB unit is defective. Disconnection/Poor connector connection
Remedy: 1 Is the wiring harness (including the ground wire) of the tape cluster securely connected to the printer? NO Securely connect the connector (the ground wire). YES Follow the procedure 2. Tape cluster PCB unit, Main PCB unit 2 Does replacing the tape cluster PCB unit solve the problem? YES Finish. NO Replace the main PCB unit.
Code: E023
Description: The tape cluster TPH resistance rank The TPH resistance rank is not properly set by DIPSW of the tape cluster PCB. DIPSW setting of the tape cluster PCB cannot be detected normally.
Causes: The TPH resistance rank setting is defective. The tape cluster PCB unit is defective.
Remedy:
Code: E024
Description: Disconnection/short circuit of the tape cluster thermistor The thermistor of the tape cluster PCB detects the abnormal temperature.
Causes: The tape cluster PCB unit is defective.
Remedy:
Code: E030
Description: EEPROM (for the standard) Write/readout to the standard is defective.
Causes: The EEPROM PCB unit is defective. The main PCB unit is defective. Disconnection/Poor connector connection
Remedy:
Code: E031
Description: EEPROM (for the key card) Write/readout to the key card is defective.
Causes: The key card EEPROM PCB unit is not initialized. The key card EEPROM PCB unit is defective. The main PCB unit is defective. Disconnection/Poor connector connection
Remedy:
Code: E032
Description: Panel communication Communication between the main PCB and the panel PCB is defective.
Causes: Disconnection/Poor connector connection The panel PCB unit is defective. The main PCB unit is defective.