Remedy: Movement: The background correction coefficient value was not updated. Cause: Each sampling value of the background reflection output of the Front Sensor did not fall within the range from 10 or higher to 250 or less for 2 consecutive times during printing. Measures: 1. Clean the Patch Sensor window. 2. Check the connector connection of the Patch Sensor. 3. Check the connector connection of the Patch Sensor Shutter Solenoid. 4. Replace the Patch Sensor Unit.
Code: 10 0007
Description: Patch Sensor error 2
Causes:
Remedy: Movement: The background correction coefficient value was not updated. Cause: Each sampling value of the background reflection output of the Front Sensor did not fall within the range from 10 or higher to 250 or less for 2 consecutive times during printing. Measures: 1. Clean the Patch Sensor window. 2. Check the connector connection of the Patch Sensor. 3. Check the connector connection of the Patch Sensor Shutter Solenoid. 4. Replace the Patch Sensor Unit.