Description: Error in temperature rising of the Fixing Assembly
Causes: The temperature of the Fixing Assembly did not reach a certain temperature within the specified period of time.
Remedy: 1. Check the harness/connector connection between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
Code: E001-0000
Description: Abnormal high temperature of the Fixing Assembly
Causes: It was detected that the temperature of the Fixing Assembly was abnormally high.
Remedy: 1. Check the harness/connector connection between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
Code: E003-0000
Description: Abnormal low temperature of the Fixing Assembly
Causes: It was detected that the temperature of the Fixing Assembly was abnormally low.
Remedy: 1. Check the harness/connector connection between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
Code: E004-0000
Description: Drive circuit error
Causes: The zero cross signal was not detected for the specified period of time or more.
Remedy: 1. Check the harness/connector connection between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
Code: E014-0000
Description: Error in startup of the Main Motor
Causes: Revolution of the Main Motor did not reach the specified value.
Remedy: 1. Check the harness/connector connection between the Main Motor and the DC Controller PCB. 2. Replace the Main Motor. 3. Replace the DC Controller PCB.
Code: E014-0001
Description: Error in startup of the Main Motor
Causes: Revolution of the Main Motor was out of the specified range.
Remedy: 1. Check the harness/connector connection between the Main Motor and the DC Controller PCB. 2. Replace the Main Motor. 3. Replace the DC Controller PCB.