PrintCopy.info service

Canon iR2018

Error Codes List page 6

  • Code: E575-0002
  • Description: - Stack delivery motor or finisher controller PCB failure
    - Stack delivery HP sensor failure
    The stack delivery motor was driven for 2000 ms in the HP sensor escape direction, but the stack delivery HP sensor did not turn off.
  • Remedy: - Check the connector of the stack delivery HP sensor. - Check the connector of the stack delivery motor. - Check the connector of the stack delivery HP sensor. - Replace the stack delivery motor. - Replace the finisher controller PCB.
  • Code: E584-0001
  • Description: Shutter drive motor or finisher controller PCB failure
    - Shutter open detection sensor failure - Shutter clutch failure The shutter open sensor did not turn on when 1000 ms have lapsed since the shutter unit had performed open operation, resulting in incomplete open operation.
  • Remedy: - Check the connector of the shutter open sensor. - Check the connector of the shutter clutch. - Check the connector of the shutter motor. - Replace the shutter open sensor. - Replace the shutter clutch. - Replace the shutter drive motor. - Replace the finisher controller PCB.
  • Code: E584-0002
  • Description: - Shutter drive motor or finisher controller PCB failure
    - Shutter open detection sensor failure - Shutter clutch failure The shutter open sensor did not turn off when 1000 ms have lapsed since the shutter unit had performed close operation, resulting in incomplete close operation.
  • Remedy: - Check the connector of the shutter open sensor. - Check the connector of the shutter clutch. - Check the connector of the shutter motor. - Replace the shutter open sensor. - Replace the shutter clutch. - Replace the shutter drive motor. - Replace the finisher controller PCB.
  • Code: E716-0000
  • Description: Erroneous communication with optional cassette
    Disconnection of the optional cassette was detected after power-on, detection of normal connection to the optional cassette, and start of communication.
  • Remedy: - Check the connectors of the optional cassette PCB and DC controller PCB. - Replace the optional cassette PCB for normal connection. - Replace the DC controller PCB.
  • Code: E719-0000
  • Description: Erroneous communication with card reader (serial communication)
    - Disconnection from the card reader has been detected since communication started after confirmation of normal connection to the card reader (after power-on).
    - A serial communication error has occurred. (The serial communication error cannot be recovered.)
  • Remedy: - Check the connectors of the card reader and image processor PCB. - Replace the card reader for normal connection. - Replace the image processor PCB.
  • Code: E719-0002
  • Description: Erroneous communication with coin vendor (serial communication)
    - Disconnection from the coin vendor has been detected since communication started after confirmation of normal connection to the coin vendor (after power-on). - A serial communication error has occurred. (The serial communication error cannot be recovered.)
  • Remedy: - Check the connection between the image processor PCB and serial PCB. - Check the connectors of the serial PCB and coin vendor for normal connection. - Replace the serial PCB. - Check the coin vendor. - Replace the image processor PCB.