  • Code: E001-0000
  • Description: Abnormal high temperature in Main Thermistor 1, 2
    Main Thermistor 1, 2 (TH1) detects 260 deg C or more for 0.2 sec.
  • Remedy: 1. Go through the following: DISPLAY > ANALOG > FIX-C, or DISPLAY > ANALOG > FIX-E; if it’s less than 260 deg C, go through the following to clear the error: COPIER>FUNCTION>CLEAR>ERR; and then turn OFF/ ON the power. It it’s 260 deg C or more, do not turn on the power before replacing the Film Unit. 2. Replace the Film Unit. 3. Replace the Shutter Unit. 4. Replace the DC Controller PCB (UN1). NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR.
  • Code: E001-0001
  • Description: Abnormal high temperature in Sub Thermistor 1, 2
    Sub Thermistor 1, 2 (TH1) detects 275 deg C or more for 0.2 sec.
  • Remedy: 1. Go through the following: DISPLAY > ANALOG > FIX-E2 or DISPLAY > ANALOG > FIX-E3; if it’s less than 275 deg C, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR; and then turn OFF and then ON the power. If it’s 275 deg C or more, do not turn on the power before replacing the Film Unit. 2. Replace the Film Unit. 3. Replace the Shutter Unit. 4. Go through the following to check drive of FM5 and FM6: COPIER > FUNCTION > PART-CHK > FAN; if not working properly, replace the fan. 5. Replace the DC Controller PCB (UN1). NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR.
  • Code: E001-0003
  • Description: High temperature error detected by hardware
    Hardware detects abnormal high temperature of the Thermistor (Main Thermistor 1: 264 deg C, Main Thermistor 2: 265 deg C, Sub Thermistor 1, 2: 280 deg C) for 400 msec consecutively.
  • Remedy: 1. If the detected temperature of the Thermistor is less than the abnormal high temperature specified for Thermistor, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR; and then turn OFF and then ON the power. If it’s at abnormally high temperature, do not turn on the power before replacing the Film Unit. 2. Replace the Film Unit. 3. Replace the Shutter Unit. 4. Go through the following to check drive of FM5 and FM6: COPIER > FUNCTION > PART-CHK > FAN; if the not working properly, replace the fan. 5. Replace the DC Controller PCB (UN1). NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR.
  • Code: E003-0000
  • Description: Error detected when the Heater is ON
    After the Heater was turned ON, Main Thermistor 2, Sub Thermistor 1 or Sub Thermistor 2 detects 21 deg C or more and 50 deg C or less for 3 sec.
  • Remedy: 1. Go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR; and then turn OFF and then ON the power. 2. Check connection of the Connectors (Thermistor Connector and AC Connector). 3. Replace the Film Unit. 4. Replace the Shutter Unit. 5. Replace the DC Controller PCB (UN1). NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR.
  • Code: E003-0001
  • Description: Abnormal detection during paper feeding
    During print control, Sub Thermistor detects 70 deg C or less from the target temperature for 5 sec.
  • Remedy: 1. Go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR; and then turn OFF and then ON the power. 2. Check for open circuit inside the Fixing Assembly and any disconnection of the connector. 3. Replace the Film Unit. 4. Replace the Shutter Unit. 5. Replace the DC Controller PCB (UN1). NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR.
  • Code: E003-0002
  • Description: Abnormal low temperature when the Heater is ON (disconnection detected)
    After the Heater was turned ON, any of the Thermistors detects 20 deg C or less for 3 sec.
  • Remedy: 1. Go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR; and then turn OFF and then ON the power. 2. Check connection of the Connectors (Thermistor Connector and AC Connector). 3. Replace the Film Unit. 4. Replace the Shutter Unit. 5. Replace the DC Controller PCB (UN1). NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR.