PrintCopy.info service

Canon iR Advance 8285 Pro

Error Codes List page 72

  • Code: E905-0002
  • Description: POD Deck Air Assist Fan error. [POD Deck Lite] When the Pickup Motor Cooling Fan is not locked
  • Remedy: 1. Check connector disconnection/improper connection. => Disconnect and then connect the connector. Target connector: Deck Lite Controller J30 2. Replace the Motor Cooling Fan (FM4). 3. Replace the Deck Lite Controller PCB.
  • Code: E905-0003
  • Description: POD Deck Air Assist Fan error. [POD Deck Lite] When the Pickup Motor Cooling Fan is not unlocked
  • Remedy: 1. Check connector disconnection/improper connection. => Disconnect and then connect the connector. Target connector: Deck Lite Controller J30 2. Replace the Motor Cooling Fan (FM4). 3. Replace the Deck Lite Controller PCB.
  • Code: E906-0001
  • Description: POD Deck Air Heater error. [POD Deck Lite] Air Heater high temperature error When 120 deg C or higher temperature is detected for 1 second consecutively
  • Remedy: 1. Check connector disconnection/improper connection. => Disconnect and then connect the connector. Target connector: Deck Lite Controller J03, J05 BoxDriver J52, J54, J58, J59 2. Replace the Air Heater. 3. Replace the Deck Lite Controller PCB.
  • Code: E906-0002
  • Description: POD Deck Air Heater error. [POD Deck Lite] Air Heater low temperature error When the heater does not become Ready although a specified period of time has passed
  • Remedy: 1. Check connector disconnection/improper connection. => Disconnect and then connect the connector. Target connector: Deck Lite Controller J03, J05 BoxDriver J52, J54, J58, J59 2. Replace the Air Heater. 3. Replace the Deck Lite Controller PCB.
  • Code: E996-xxxx
  • Description: Timeout error. The DC Controller is not stopped. The Detailed Code varies according to the state transition of the software
  • Remedy: Turn OFF and then ON the main power.