PrintCopy.info service

Canon iR Advance 6275

Error Codes List page 54

  • Code: E906-0002
  • Description: POD Deck Air Heater errorr high.
    [POD Deck Lite] Air Heater low temperature error When the heater does not become Ready although a specified period of time has passed.
  • Remedy: 1. Check connector disconnection/improper connection. - > Disconnect and then connect the connector. Target connector: Deck Lite Controller J03, J05 BoxDriver J52, J54, J58, J59 2. Replace the Air Heater. 3. Replace the Deck Lite Controller PCB.
  • Code: E996-xxxx
  • Description: Timeout error
    The DC Controller is not stopped. The Detailed Code varies according to the state transition of the software.
  • Remedy: Turn OFF and then ON the main power.