  • Code: E000-0000
  • Description: Error in temperature rising of the Fixing Assembly
  • Causes: The temperature of the Fixing Assembly did not reach a certain temperature within the specified period of time.
  • Remedy: 1. Check the harness/connector between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
  • Code: E001-0000
  • Description: Abnormal high temperature of the Fixing Assembly
  • Causes: It was detected that the temperature of the Fixing Assembly was abnormally high.
  • Remedy: 1. Check the harness/connector between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
  • Code: E003-0000
  • Description: Abnormal low temperature of the Fixing Assembly
  • Causes: It was detected that the temperature of the Fixing Assembly was abnormally low.
  • Remedy: 1. Check the harness/connector between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
  • Code: E004-0000
  • Description: Drive circuit error
  • Causes: The zero cross signal was not detected for the specified period of time or more.
  • Remedy: 1. Check the harness/connector between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
  • Code: E004-0005
  • Description: Fixing Relay fusion error
  • Causes: At power ON or recovery from sleep mode, a zero cross signal was detected three times during the period of 100 ms after completion of CPU initialization.
  • Remedy: 1. Check the harness/connector between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
  • Code: E014-0000
  • Description: Error in startup of the Main Motor
  • Causes: Revolution of the Main Motor did not reach the specified value.
  • Remedy: 1. Check the harness/connector between the Main Motor and the DC Controller PCB. 2. Replace the Main Motor. 3. Replace the DC Controller PCB.