Xerox Phaser 6180 MFP
Error Codes List page 16
|
- Code: 117-352
- Description: Controller Error Communication between the Scanner and the Controller has failed. The following troubleshooting procedure applies to this error.
- Causes: • Scanner Controller Board, PL9.1.1 • ADF Scanner Assembly, PL11.1.1
- Remedy: 1 Check the Scanner Lock. Is the Scanner Lock at the Unlock position? Go to step 2. Set the Scanner Lock to the Unlock position. 2 1. Check the wiring harness connectors P/J60, P/J62, P/J63, P/ J64, and P/J65 on the Scanner Controller Board. Reseat the connectors. 2. Does the error still occur when the printer power is turned On? Go to step 3. Complete. 3 1. Replace the ADF Scanner Assembly. 2. Does the error still occur when the printer is turned On? Replace the Scanner Controller Board. Complete.
- Code: 193-700
- Description: Non-Xerox Print Cartridge Installed The Printer does not have a genuine Xerox Print Cartridge installed. The following troubleshooting procedure applies to this error.
- Causes: • Print Cartridge (Y/M/C/K), PL5.1.17-20 • MCU Board, PL9.2.13 • CRUM Harness, PL10.1.9
- Remedy: 1 1. Check the Print Cartridge(s) for correct installation. 2. Is the Print Cartridge(s) correctly installed? Go to step 3. Reseat the Print Cartridge(s). Go to step 2. 2 Does the error still occur when the printer is turned On? Go to step 4. Complete. 3 Is the Print Cartridge a Xerox Print Cartridge? Go to step 5. Install a Xerox Print Cartridge. 4 1. Check the CRUM Connector for correct installation. 2. Is the connector securely connected? Go to step 5. Reseat the CRUM Connector. Go to step 5. 5 1. Check the wiring harness connector(s) between the CRUM Connector and the MCU Board. • Yellow: P/J31 and P/J311 • Magenta: P/J31 and P/J312 • Cyan: P/J31 and P/J313 • Black: P/J31 and P/J314 2. Is the connector(s) securely connected? Go to step 6. Reconnect the connector(s). Go to step 6. 6 Check the CRUM Harness for continuity. 1. Disconnect the wiring harnesses from the Connector CRUM and MCU Board. • Yellow: P/J31 and P/J311 • Magenta: P/J31 and P/J312 • Cyan: P/J31 and P/J313 • Black: P/J31 and P/J314 2. Check continuity between P/J connectors: • Yellow: P/J31 <=> P/J311 • Magenta: P/J31 <=> P/J312 • Cyan: P/J31 <=> P/J313 • Black: P/J31 <=> P/J314 Go to step 7. Replace the CRUM Harness. 7 Check the CRUM Connector for damages. Is the CRUM Connector damaged? Replace the CRUM Connector. Go to step 8. 8 1. Replace the CRUM Connector. 2. Does the error still occur when the printer is turned On? Go to step 9. Complete. 9 1. Replace the Print Cartridge. 2. Does the error still occur? Replace the MCU Board. Complete.