  • Code: 117-352
  • Description: Controller Error Communication between the Scanner and the Controller has failed. The following troubleshooting procedure applies to this error.
  • Causes: • Scanner Controller Board, PL9.1.1 • ADF Scanner Assembly, PL11.1.1
  • Remedy: 1 Check the Scanner Lock. Is the Scanner Lock at the Unlock position? Go to step 2. Set the Scanner Lock to the Unlock position. 2 1. Check the wiring harness connectors P/J60, P/J62, P/J63, P/ J64, and P/J65 on the Scanner Controller Board. Reseat the connectors. 2. Does the error still occur when the printer power is turned On? Go to step 3. Complete. 3 1. Replace the ADF Scanner Assembly. 2. Does the error still occur when the printer is turned On? Replace the Scanner Controller Board. Complete.
  • Code: 193-700
  • Description: Non-Xerox Print Cartridge Installed The Printer does not have a genuine Xerox Print Cartridge installed. The following troubleshooting procedure applies to this error.
  • Causes: • Print Cartridge (Y/M/C/K), PL5.1.17-20 • MCU Board, PL9.2.13 • CRUM Harness, PL10.1.9
  • Remedy: 1 1. Check the Print Cartridge(s) for correct installation. 2. Is the Print Cartridge(s) correctly installed? Go to step 3. Reseat the Print Cartridge(s). Go to step 2. 2 Does the error still occur when the printer is turned On? Go to step 4. Complete. 3 Is the Print Cartridge a Xerox Print Cartridge? Go to step 5. Install a Xerox Print Cartridge. 4 1. Check the CRUM Connector for correct installation. 2. Is the connector securely connected? Go to step 5. Reseat the CRUM Connector. Go to step 5. 5 1. Check the wiring harness connector(s) between the CRUM Connector and the MCU Board. • Yellow: P/J31 and P/J311 • Magenta: P/J31 and P/J312 • Cyan: P/J31 and P/J313 • Black: P/J31 and P/J314 2. Is the connector(s) securely connected? Go to step 6. Reconnect the connector(s). Go to step 6. 6 Check the CRUM Harness for continuity. 1. Disconnect the wiring harnesses from the Connector CRUM and MCU Board. • Yellow: P/J31 and P/J311 • Magenta: P/J31 and P/J312 • Cyan: P/J31 and P/J313 • Black: P/J31 and P/J314 2. Check continuity between P/J connectors: • Yellow: P/J31 <=> P/J311 • Magenta: P/J31 <=> P/J312 • Cyan: P/J31 <=> P/J313 • Black: P/J31 <=> P/J314 Go to step 7. Replace the CRUM Harness. 7 Check the CRUM Connector for damages. Is the CRUM Connector damaged? Replace the CRUM Connector. Go to step 8. 8 1. Replace the CRUM Connector. 2. Does the error still occur when the printer is turned On? Go to step 9. Complete. 9 1. Replace the Print Cartridge. 2. Does the error still occur? Replace the MCU Board. Complete.
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us