Catalog
-
Sign In
-
Contacts
-
Forum
-
Eng
Roland SP300 VersaCamm
Error Codes List page 3
|
|
- Code: 0121
- Description: Thermistor Error (Dryer)
Thermistor of the Dryer doesn't work correctly.
- Causes: Thermistor of the Dryer is broken. There is a cut-line/short in the wiring of the Thermistor.
- Remedy: 1) Check the wirings of Dryer 2) Thermistor Replacement
- Code: 0125
- Description: Heater Error (Print Heater)
Print Heater doesn't work correctly. Temperature of the Print Heater is over 60 degree Celsius.
- Causes: There is a cut-line/short in the wiring of the Print Heater. Thermostat is broken. Thermistor is broken.
- Remedy: 1) Check the wirings of Print Heater 2) Thermostat Replacement 3) Thermistor Replacement
- Code: 0126
- Description: Heater Error (Dryer)
Dryer doesn't work correctly. Temperature of the Dryer is over 60 degree Celsius.
- Causes: There is a cut-line/short in the wiring of the Dryer. Thermostat is broken. Thermistor is broken.
- Remedy: 1) Check the wirings of Dryer 2) Thermostat Replacement 3) Thermistor Replacement