Description: Software operation error Software attempted an unexpected operation.
Causes: • Parameter error • Internal parameter error • Insufficient work memory • Operation error caused by abnormalities that are normally undetectable.
Remedy: • Turn the main power OFF/ON. • Reinstall the software of the controller board (PCB3) and BiCU (PCB2).
Code: SC991-00
Description: Recoverable software operation error Software attempted an unexpected operation. SC991 covers recoverable errors as opposed toCS990.
Causes: • Parameter error • Internal parameter error • Insufficient work memory • Operation error caused by abnormalities that are normally undetectable.
Remedy: Logging only
Code: SC992-00
Description: Undefined SC issued. An SC, that is not controlled by the system, occurred.
Causes: • An SC for the previous model was used mistakenly, etc. • Basically a software bug.
Remedy: Turn the main power OFF/ON.
Code: SC994-00
Description: Operation error caused by abnormalities that are normally undetectable. An error occurred because the number of records exceeded the limit for images managed in the service layer of the firmware.
Causes: This can occur if there are too many application screens open on the operation panel.
Remedy: Logging only.
Code: SC998-00
Description: Application start error • No application was registered to system within a specified time after the main power was turned ON. (No application starts/All applications have been terminated abnormally) • Application started but cannot be drawn now for some reason.
Causes: • Software bug (mainly the application) • The optional RAM/DIMM/boards, required by the application program, are not installed correctly.
Remedy: • Check the optional RAM/DIMM/boards required by the application program. • Check if the combination of downloaded programs are correct. • Replace the controller board (PCB3).