PrintCopy.info service

Ricoh M0A0 MP402SPF

Error Codes List page 21

  • Code: SC900-00
  • Description: Electronic counter error
    The electronic total counter value is not the specified value. This error is detected when the counter moves forward.
  • Causes: • The NVRAM connection is not correct.
    • The NVRAM is defective.
    • The NVRAM data is corrupted.
    • The data was written in the wrong area due to external factors.
    • When PRT received signals at SRM, the requested count is not completed.
  • Remedy: Replace the NVRAM.
  • Code: SC990-00
  • Description: Software performance error
    The software attempted to make an unexpected operation.
  • Causes: • Incorrect argument
    • Incorrect internal parameter
    • Insufficient working memory
    • Abnormal performance caused by an error that cannot be detected in normal SC detection due to hardware specifications
  • Remedy: • Turn the main power switch off and on.
    • Reinstall the software of the controller board.
    • Reinstall the software of the engine board.
  • Code: SC991-00
  • Description: Software Error (Operation Can Continue)
    The software performed in an unexpected way. By taking recovery measures, further operation is possible.
  • Causes: • The parameter is invalid.
    • There is insufficient work memory.
    • This SC is caused by errors that are not normally detected from the hardware.
  • Remedy: Not required
  • Code: SC992-00
  • Description: Undefined SC
    An undefined SC has occurred.
  • Causes: There is a bug in the software.
  • Remedy: Turn the main power switch off and on.
  • Code: SC997-00
  • Description: Application function selection error
    The application did not function normally after pressing the application key on the operation panel.
  • Causes: There is a bug in the software.
  • Remedy: Check if the options required by the application (RAM, DIMM, boards) are installed properly.
    Check whether downloaded applications are correctly configured.
  • Code: SC998-00
  • Description: Application start error
    • After power ON, no application program was registered to the system within the specified period of time. (No application started or ended normally.).
    • Even though the application started up, it cannot be rendered due to an unknown fault.
  • Causes: • There is a bug in the software.
    • The options required by the application (RAM, DIMM, board) are not installed.
  • Remedy: • Turn the main power OFF then ON.
    • Check the RAM, DIMM, and boards.
    • Check the application configurations.
    • Replace the controller board.