Description: Recoverable software operation error Software attempted an unexpected operation. SC991 covers recoverable errors as opposed to SC990.
Causes: • Parameter error • Internal parameter error • Insufficient work memory • Operation error caused by abnormalities that are normally undetectable.
Remedy: Logging only
Code: SC995-01
Description: CPM setting error 1 Comparison of machine serial number (11 digits) and machine identification code. Details: • Machine serial number cannot be identified because of BICU replacement or malfunctioning. • Machine serial number cannot be identified because of NV-RAM replacement
Causes: Machine serial number (11 digits) or machine identification code does not match.
Remedy: • Enter the machine serial number using SP5-811, and then turn the power on/off. • Attach the NV-RAM that was installed previously.
Code: SC995-02
Description: CPM setting error 2 Comparison of machine serial number (11 digits) and machine identification code. Details: Machine serial number cannot be identified because of NV-RAM replacement or malfunctioning.
Causes: Machine serial number (11 digits) or machine identification code does not match.
Remedy: • Attach the NV-RAM that was installed previously. • Download data on the NV-RAM using SP5-825.
Code: SC995-03
Description: CPM setting error 3 Comparison of machine serial number (11 digits) and machine identification code. Details: Unable to recognize machine identification code because the controller was replaced incorrectly or is malfunctioning.
Causes: Machine serial number (11 digits) or machine identification code does not match.
Remedy: Replace it with a compatible controller.
Code: SC995-04
Description: CPM setting error 4 Comparison of machine serial number (11 digits) and machine identification code.
Causes: Machine serial number (11 digits) or machine identification code does not match.
Remedy: Return the parts to the original configuration, and then replace them according to the manual.