Description: Clamper Motor Failure The MPU cannot detect the clamper position sensor signal (open or closed) within 3.0 seconds after the clamper motor turns on.
Causes: Clamper drive Clamper sensors Clamper motor MPU board Main motor encoder Master eject position sensor
Code: E-01
Description: Cutter error The cutter HP sensor does not turn on within 3.0 seconds after the cutter motor turns on.
Causes: Cutter drive Cutter switch Cutter motor
Code: E-02
Description: Paper Table Drive error The paper height sensor or the table lower limit sensor does not turn on within 7.5 seconds after the table motor turns on. Paper height sensor 1 or 2 does not turn on within 1 second after the paper height sensor 1 or 2 turn on.
Causes: Paper table drive Paper table motor Paper height sensor 1 or 2 Paper table lower limit sensor Gears Paper table spring
Code: E-04
Description: Thermal Head Overheat Temperature of the thermal head is greater than 65°C when the Start key is pressed.
Causes: Overheat (wait for the thermal head to cool down) Thermal head
Code: E-06
Description: Main Motor Lock The CPU cannot detect the master eject position sensor (drum HP) signal within 5.0 seconds after the main motor turns on.
Causes: Main motor drive Main motor Motor drive board Master eject position sensor
Code: E-09
Description: Thermal Head Thermistor Open The thermistor output voltage is over 4.432 volts.
Causes: Thermal head thermistor Thermal head connector