Description: Pressure roller lamp full-power operation error When full-power operation occurs during reheating, the main motor is not running and the difference between the current temperature and that of 60 seconds ago is 18°C or less.
Description: Hot roller lamp fullpower operation error When full-power operation occurs during reheating, the main motor is not running and the difference between the current temperature and that of 60 seconds ago is 18°C or less.
Causes: Hot roller thermistor, hot roller lamp connector, MCU
Code: 57
Description: Print command error When an abnormal combination of print commands is received.
Causes:
Code: 59
Description: Temperature sensor error 5 V (4.75 V) or more has continuously been detected for five seconds.
Causes: Temperature sensor
Code: 60
Description: Humidity sensor error 5 V (4.75 V) or more has continuously been detected for five seconds.