PrintCopy.info service

OKI C3100

Error Codes List page 10

  • Code: 903, 904
  • Display: Power off/on 903:Error 904:Error
  • Description: Abnormal temperature detected by belt thermistor (high-temp or low temp.)
  • Remedy: Is belt thermistor cable setting proper? Does error reoccur?
    Connect cable set properly again. Turn power ON again. Replace belt thermistor and leave aside for 30 min. Then turn power ON again.
  • Code: 905
  • Display: Service call 905:Error
  • Description: An open error of frame thermistor (defective thermistor or improper connection) detected.
  • Remedy: Does error reoccur? Turn power ON again. Replace the fuser unit.
  • Code: 906
  • Display: Service call 906:Error
  • Description: A short circuit error of frame thermistor (defective improper) detected.
  • Remedy: Does error reoccur? Turn power ON again. Replace the fuser unit.
  • Code: 907
  • Display: Service call 907:Error
  • Description: A high temperature error (over 150°C) of frame thermistor detected.
  • Remedy: Does error reoccur? Turn power ON again. Replace the fuser unit.
  • Code: 908
  • Display: Service call 908:Error
  • Description: A low temperature error (below [environmental temperature minus 10]°C) of frame thermistor detected.
  • Remedy: Does error reoccur? Turn power ON again. Replace the fuser unit.
  • Code: FOC, F0D, FFE, FFF
  • Display: Power off/on 203:Error
    204:Error 207:Error
    208:Error 210:Error ~ 214:Error
    F0C:Error F0D:Error(C5400 only)
    FFE:Error(C5400 only) FFF:Error
  • Description: An error was detected of the CU program. (203~214 is not occure in usual operating.)
  • Remedy: Reinstall the CU board. Is the error message displayed again? After turn power OFF, check connections between CU board and PU board. Then turn power ON again.