- Code: SC77-49
- Description: When non-volatile memory is being accessed, no response is obtained for a specified period of time.
- Causes: FD control board (FDCB)
- Remedy: The main body stops immediately to turn OFF the RL1 (main).
- Code: SC77-58
- Description: When the FD is unready, a signal to start operations is received from the main body.
- Causes: Irregular operations. Recovery by turning the power ON and OFF.
- Remedy: The main body stops immediately to turn OFF the RL1 (main).
- Code: SC77-59
- Description: The communication message queue between the tasks in the FD is full.
- Causes: Irregular operations. Recovery by turning the power ON and OFF.
- Remedy: The main body stops immediately to turn OFF the RL1 (main).
- Code: SC80-40
- Description: The ISW information is not written. Or, the ROM check of the FD results in an error.
- Causes: FD control board (FDCB) Wiring harness between the FDCB and the main bo
- Remedy: The main body stops immediately to turn OFF the RL1 (main).
- Code: SC80-42
- Description: The ISW information is not written. Or, the ROM check of the FNS results in an error.
- Causes: FNS control board (FNSCB) Wiring harness between the FNSCB and the main body
- Remedy: The main body stops immediately to turn OFF the RL1 (main).