Description: Tray 1 feeder up/down abnormality
• The paper feed tray 1 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Remedy: 1 Check the M8 connector for proper connection and correct as necessary. 2 Check the connector of M8 for proper drive coupling and correct as necessary. 3 PS8 I/O check, sensor check. 4 M8 operation check. 5 Change M8. 6 Change PRCB.
Code: C0204
Description: Tray 2 feeder up/down abnormality
• The paper feed tray 2 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Remedy: 1 Check the M9 connector for proper connection and correct as necessary. 2 Check the connector of M9 for proper drive coupling and correct as necessary. 3 PS15 I/O check, sensor check. 4 M9 operation check. 5 Change M9. 6 Change PRCB.