Remedy: Status 1 Fuser Cover Status is detected correctly. “H” = Cover Open / “L” = Cover Closed Yes OK Fuser Exit Switch (L) SW2 Fuser Exit Switch (R) SW3 2 Replacing SW2 or SW3 recovers door status. Yes OK PW13555 3 Replacing PW13555 recovers Door Status. Yes OK Main Control PCB (PW13520) 4 Replacing PW13520 PCB recovers Door Status. Yes OK
Remedy: Status 1 Paper Exit Door Status is detected correctly. “H” = Door Open / “L” = Door Closed Yes OK Upper Exit Switch (L) SW7 Upper Exit Switch (R) SW8 2 Replacing SW7 or SW8 recovers door status. Yes OK PW13555 3 Replacing PW13555 recovers Door Status. Yes OK Main Control PCB (PW13520) 4 Replacing PW13520 PCB recovers Door Status. Yes OK
Code: U-00002000
Description: Left Side Cover Open
Causes: Input Check Mode No. 00518 Left Cover Status (“H” = Open)
Remedy: Status 1 Left Cover Status is detected correctly. “H” = Cover Open / “L” = Cover Closed Yes OK Left Door Switch SW5 2 Replacing SW5 recovers door status. Yes OK PW13555 3 Replacing PW13555 recovers Door Status. Yes OK Main Control PCB (PW13520) 4 Replacing PW13520 PCB recovers Door Status. Yes OK
Remedy: Status 1 Cutter Cover L Status is detected correctly. “H” = Cover Open / “L” = Cover Closed Yes OK Cutter Cover SW6 2 Replacing SW6 recovers door status. Yes OK PW13555 3 Replacing PW13555 recovers Door Status. Yes OK Main Control PCB (PW13520) 4 Replacing PW13520 PCB recovers Door Status. Yes OK
Code: U-01000000, U-02000000
Description: U-01000000 Process Unit 1 Open U-02000000 Process Unit 2 Open U-04000000 Process Unit 3 Open U-08000000 Process Unit 4 Open
Causes: Input Check Mode No. 00018 Process Unit Status:K (“H” = Open) Input Check Mode No. 00118 Process Unit Status:C (“H” = Open) Input Check Mode No. 00218 Process Unit Status:M (“H” = Open) Input Check Mode No. 00318 Process Unit Status:Y (“H” = Open)
Remedy: Process Unit Unlock 1 This Status is indicated when Process Unit is Unlocked (Process Unit is pulled out) while other conditions are normal. Closing and Locking Process unit by screws recovers Unit Open Status. Yes OK <Note> When following Connectors were unplugged E-0310 Out of Process 1 Developer Error will be indicated. J286A, J230A, J240A, J320A. E-0310 Out of Process 1 Developer Error (J286A, J230A, J240A, J320A) E-0410 Out of Process 2 Developer Error (J286B, J230B, J240B, J320B) E-0510 Out of Process 3 Developer Error (J286C, J230C, J240C, J320C) E-0610 Out of Process 4 Developer Error (J286D, J230D, J240D, J320D)
Code: U-04000000, U-08000000
Description: U-01000000 Process Unit 1 Open U-02000000 Process Unit 2 Open U-04000000 Process Unit 3 Open U-08000000 Process Unit 4 Open
Causes: Input Check Mode No. 00018 Process Unit Status:K (“H” = Open) Input Check Mode No. 00118 Process Unit Status:C (“H” = Open) Input Check Mode No. 00218 Process Unit Status:M (“H” = Open) Input Check Mode No. 00318 Process Unit Status:Y (“H” = Open)
Remedy: Process Unit Unlock 1 This Status is indicated when Process Unit is Unlocked (Process Unit is pulled out) while other conditions are normal. Closing and Locking Process unit by screws recovers Unit Open Status. Yes OK <Note> When following Connectors were unplugged E-0310 Out of Process 1 Developer Error will be indicated. J286A, J230A, J240A, J320A. E-0310 Out of Process 1 Developer Error (J286A, J230A, J240A, J320A) E-0410 Out of Process 2 Developer Error (J286B, J230B, J240B, J320B) E-0510 Out of Process 3 Developer Error (J286C, J230C, J240C, J320C) E-0610 Out of Process 4 Developer Error (J286D, J230D, J240D, J320D)