Remedy: • Check that the Drop Detector Cable is NOT broken or damaged.• Check that the Drop Detector cable is correctly connected to the Service Station Cable.• Remove the Drop Detector and make sure that there are no obstacles inside which are blocking the sensor.• Replace the Drop Detector Assembly.• If the Error Code continues, replace the Electronics Module
Code: 0C0032
Description: Drop Detector not Calibrated for all Printheads.
Remedy: • Perform the Service Station Calibration.• Replace the Drop Detector Assembly.• If the Error Code continues, replace the Electronics Module
Code: 0C1000
Description: Primer not Calibrated.
Remedy: • Perform the Service Station Calibration.• Make sure that the Primer Arm is not damaged. If the Primer Arm is damaged, replace the Service Station.• Replace the Electronics Module.
Code: 0C1001
Description: Primer Shutdown Error.
Remedy: • Check that the Primer Stepper-Motor Cable is NOT broken or damaged and that the Primer arm moves freely from side to side.• Replace the Service Station.• If the Error Code continues, replace the Electronics Module